Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberESC14-00657
StatusFinaled
Name DANIEL FRISBY
Site Address 6400 E WARM SPRINGS AVE
Project NameRIVER HEIGHTS SUB #6
Customer Number 
ePlanReviewNo
Description
ESC site map and SWPPP submitted with rough grading permit application. Groundwater approximately 18 ft bgs. MS4 drianage in area is to underground seepage beds; Maynard Gulch creek lies to the west of development (typically dry). SWPPP submitted describes BMPs for rough grading, utility intallation, and curbing and roadwork. Site prep/pre-construction meeting are required. Project is scheduled between July to December 2014. Dust control will be required and is listed in SWPPP. Site stabilization required at end of construction. Silt fence to be installed at northwest boundary of project.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final3/20/20183/20/20183/20/2018PPASS
DetailsAndy J. Long
All parcels complete and stabilized. Temporary storm drain sediment protection has been removed from all inlets in River Heights phase 6. ESC permit conditions satisfied.
General Inspection3/1/20183/1/20183/1/2018 PASS
DetailsMichael Zawacki
Sent message to Syman and RP to remove DI protection. Will final permit when removed.
General Inspection1/29/20181/29/20181/29/2018 PEND
DetailsAndy J. Long
Subdivision complete.

To final:
- remove all sediment filter bags from storm drains in sub
- pick up loose trash from construction actiivty that is on the south side of Warm Springs
General Inspection12/28/201712/28/201712/29/2017 CANC
DetailsAndy J. Long
Site Final11/27/201711/27/201711/27/2017PNR
DetailsAndy J. Long
Need to remove all temporary BMPs drop inlet protection sediment bags in River Heights #6.

All SFHs complete, all areas stabilized. Ready for ESC final once DI bags have been removed.
General Inspection11/6/201711/6/201711/6/2017 PASS
DetailsMichael Zawacki
Building complete and final stabalization achieved. DI protection still installed.
General Inspection10/5/201710/5/201710/5/2017 CANC
DetailsAndy J. Long
General Inspection9/4/20179/4/20179/5/2017 CANC
DetailsAndy J. Long
General Inspection8/3/20178/3/20178/3/2017 CANC
DetailsAndy J. Long
General Inspection7/3/20177/3/20177/3/2017 PART
DetailsMelissa Jannusch
Sent message to Zack of Brighton requesting that the DI bags on signal rock and playwright streets be removed so permit can be closed.
General Inspection6/1/20176/1/20176/1/2017 PEND
DetailsAndy J. Long
All parcels within RH#6 are near completion. Still need to remove all temporary DI bags in storm drains through out subdivsion to get Site Final.
General Inspection5/1/20175/1/20175/1/2017PPEND
DetailsAndy J. Long
Need to remove all temporary BMPs from storm drains in pahse #6. All lots have landscaped homes, all common areas stabilized.
Site Final4/20/20174/21/20174/21/2017ANR
DetailsMelissa Jannusch
Not ready to final. DI bags are still on signal rock and playwright. WIP on several SFHs.
General Inspection4/20/20174/20/20174/20/2017 CANC
DetailsAndy J. Long
General Inspection3/20/20173/20/20173/20/2017 PASS
DetailsMelissa Jannusch
WIP on SFHs. Sub ok. No corrections.
General Inspection2/16/20172/16/20172/16/2017 PASS
DetailsMelissa Jannusch
not ready to final. WIP on a few SFH. DI bags still in place on intersection of play right and signal rock.
General Inspection12/16/201612/16/201612/21/2016 CANC
DetailsAndy J. Long
Site Final11/15/201611/15/201611/15/2016PNR
DetailsAndy J. Long
Corrections needed before ESC final:

1. Remove DI bags on Signal Rock at both intersections with Playwright
2. Sweep up concrete dust and loose sediment where the concrete wasshout pan was placed

3. Pick up wind blown construction and employee waste on south side of Warm Springs.



Note: all DI bags except the two on Playwright on both sides of the active SFHs by Alturas should remain.
General Inspection11/4/201611/4/201611/4/2016 CANC
DetailsAndy J. Long
General Inspection10/3/201610/4/201610/5/2016APASS
DetailsAndy J. Long
DI bags have been maintained as requested during prior inspection. SFHs in progress, no trackout, wind blown trash issues, or spills observed. Concrete washout pan being utilized. No new corrections. Approved
General Inspection9/23/20169/30/201610/3/2016ACANC
DetailsAndy J. Long
check for DI bag maintenance; rescheduled
Site Final9/22/20169/23/20169/23/2016ANR
DetailsAndy J. Long
requested by Zach

Concrete washout pan is still on site and maintained(rented) by Brighton Corp. SFH work by Brighton Homes and Alturas. All lots have been sold.

Brighton Homes RP & crew to perform maitainenance on DI bags next week. Will check back 9/30.

Agreed to keep ESC permit open while the work finishes up. River Heights # 7 is now paved and is connected to this RH #6 now.

No discharges or violations. No wind blown trash on south side of Warm Springs.
General Inspection9/12/20169/12/20169/12/2016 PASS
DetailsAndy J. Long
SFHs in progress. All lots on Signal Rock now have been built upon. Subdivision BMPs installed. No trackout or discharges offsite, wind blown litter picked up weekly. No corrections requested.
General Inspection8/12/20168/12/20168/12/2016 PASS
DetailsAndy J. Long
Random Inspection7/12/20167/12/20167/12/2016PPART
DetailsAndy J. Long
Correction requests to Brighton Homes RP:

- provide new concrete washout
- dispose of old concrete washout materials
- sweep up first SFH to left on Signal Rock.
General Inspection6/16/20166/16/20166/16/2016 PART
DetailsAndy J. Long
RH#6 is mostly good condition. No trackout, fugitive dust, or discharges obsered. DIs have filter bags and trash is being contained.

Corrections needed:

-Check DI bags for maintenance, observed some full bags.
- Pick up wind blown trash on south side of Warm Springs from building sites.
General Inspection5/16/20165/16/20165/16/2016 PASS
DetailsAndy J. Long
SFHs in progress. BMPs installed. No uncontained/wind blown trash issues. No discharges on or off site observed.
General Inspection4/14/20164/14/20164/14/2016 PASS
DetailsAndy J. Long
General Inspection3/10/20163/14/20163/14/2016APASS
DetailsAndy J. Long
Streets were cleaned after retaining wall operation and haul off last week. Storm drains have inlet bags, should be checked for maintenance this week.

No active trackout; wind blown trash and materials at south side of Warm Springs are picked up weekly, only a few items at time of inspection. NO violations observed, no hillside erosion issues.
General Inspection3/10/20163/10/20163/10/2016 PART
DetailsAndy J. Long
WIP on SFHs and off haul of dirt from lower section retaining walls. Significant trackout within subdivision. Storm drains have sediment filter bags installed.

Brighton Homes RP Erbie stated streets will swept this weekend and inlet bags maintained/emptied.
General Inspection2/5/20162/8/20162/8/2016APASS
DetailsAndy J. Long
Multiple houses in progress at RH #6. No trackout, discharges, or building materials or debris leaving subdivision. Storm drains have sediment bags installed and maintained regularly. Lined washout provided. Approved.
General Inspection2/5/20162/5/20162/5/2016 CANC
DetailsAndy J. Long
rescheduled
Random Inspection1/5/20161/5/20161/5/2016APART
DetailsAndy J. Long
Corrections needed at site:

- need to inspect and maintain all DI bags since most are now unfrozen and 50% capacity or more. In particular the two inlets at Signal Rock and Warm Springs

- concrete washout at 75% capacity. New lined washout with rock access pad should be installed this week
General Inspection12/21/201512/21/201512/21/2015 FAIL
DetailsAndy J. Long
WIP on SFHs by Brighton Homes.

Significant amount of trash and windblown litter has collected on the south side of Warm Springs has not been monitored or picked up at all since correction issued 11/18.

Significant amount of muddy water running off homesites on east end of subdivision. No sediment control BMPs other than DI bags on stormdrian are installed.

Brighton Homes RP Erbie and Brighton RP Zach notified by phone.
Random Inspection11/18/201511/18/201511/18/2015PPART
DetailsAndy J. Long
No offsite discharges of sediment or other materials, no trackout. BMPs with subdivision area installed. High amount of activity on all streets and very crowded, street sweeping should occur on weekends...

Correction:
- pick up wind blown trash and construction wrappings that have blown down Signal Rock and accumulated in the weeds along the south side of Warm Springs (river side). This trash pick up should occur regularly (1x week) because the wind whips down the hill and blows everything in that area.
Tracking Control10/21/201510/21/201510/21/2015APART
DetailsAndy J. Long
Trackout from active Brighton Homes projects has extended offsite to Warm Springs Road. Has not yet been cleaned since occuring on Monday. Dirt/mud clods on south shoulder of road should be removed

Brighton Homes crew in process of cleaning up streets with brooms and bobcat with sweeping attachment. May need to get a street sweeping truck on site...

Verbal notice issued to Brighton Homes and Brighton Co.
General Inspection10/12/201510/12/201510/12/2015 PASS
DetailsAndy J. Long
WIP on homes in RH#6. No fugitive dust complaints, no trackout or discharges offsite. No hillside erosion rills or gullies observed in and around site. BMPs installed include DI bags and lined washout. Brightoh Homes has SFHs permitted individually. Approved. No corrections at this time.
General Inspection9/10/20159/10/20159/10/2015 PART
DetailsAndy J. Long
All BMPs good and active SFHs are in compliance.

1 correction:
Washout is about 75% full, new washout needed. Dispose of old washout properly.
General Inspection8/10/20158/10/20158/10/2015 CANC
DetailsAndy J. Long
access to Warm Springs Road EB from Eckert restricted currently. Inspection to be rescheduled.
Tracking Control7/10/20157/10/20157/10/2015PPART
DetailsAndy J. Long
Some erosion along the banks of the entrance blew out onto the intersection with Warm Springs and filled drop inlet with mud. Cleaning and maintenance crew was already working upon arrival - shoveling mud and dirt, emptying out inlet bags and sweeping. A street sweeper should come in later this after once the dirt has had time to dry.

I think sediment control wattles or silt fence should be installed at the entrance or else landscaping needs to be scheduled.
Random Inspection7/9/20157/9/20157/9/2015PPASS
DetailsAndy J. Long
Post precipitation event inspection found no BMP failures or other violations at River Heights #6. WIP on SFHs by Brighton Homes. Sites are currently in compliance, workers staying off muddy areas.
Random Inspection6/19/20156/19/20156/19/2015APASS
DetailsAndy J. Long
River Height's #6 has SFHs in progress. BMPs are installed and no corrections currently needed. Remaining capacity in lined concrete washout. Approved.
General Inspection5/25/20155/25/20155/26/2015 PASS
DetailsAndy J. Long
River Heights #6 has all streets and infrastructure complete. All new DIs were fitted with sediment capture bags. SFHs now under way by Brighton Homes.

Designated lined concrete washout is installed and has been utilized. No trackout or discharges off site. Some dirt on road by by concrete washout due to some hauling of stockpiles. Will be swept up per Erbie G. with Brighton Homes.

No corrections at this time. Workers keeping it clean and BMPs are currently adequate.
General Inspection4/24/20154/24/20154/24/2015PPASS
DetailsAndy J. Long
RH #6 has all roads and utilities installed. Rock Placing company installing a rock retaining wall on the lots abutting the foothills.

No hillside erosion occuring, no trackout, no turbid discharges. Individual lots will begin later this summer it appears.
General Inspection4/21/20154/21/20154/21/2015 CANC
DetailsAndy J. Long
Random Inspection3/20/20153/20/20153/20/2015APASS
DetailsAndy J. Long
River Heights #6 has curbing and storm drains installed. Road base is ready for paving/asphalt next week.

Cement curb washout was done in 3 Eco-pan containers that are soon to be serviced.

Silt fence has been removed to install sidewalk/landscaping along Warm Springs. No trackout, windblown trash, or hillside erosion. Permit is posted and SWPPP is on site.
Random Inspection3/3/20153/3/20153/3/2015PPASS
DetailsAndy J. Long
Work has resumed on River Heights #6 after winter shut down. No trackout or discharges off site. No chemical storage at site. No dust issues; earthen berm is built up along Warm Springs at the toe of the slope the subdivision is on.

No corrections at this time.
General Inspection2/17/20152/17/20152/23/2015 CANC
DetailsAndy J. Long
General Inspection1/16/20151/16/20151/16/2015 PASS
DetailsAndy J. Long
No activity at River Heights #6 currently. No discharges or trackout. Grading has been done in a way to keep runoff from upper portion of development on site. Permit posted. No corrections needed.
General Inspection12/16/201412/16/201412/16/2014 PASS
DetailsAndy J. Long
No activity at site currently. No trackout or discharges occuring. No chemical or material storage at site. Permit posted and perimeter BMPs installed.
General Inspection11/12/201411/12/201411/12/2014 PASS
DetailsAndy J. Long
Rough grading and compaction has been completed at Riverheights #6. Trenches for utilities are in progress. ESC BMPs included permit signage, stabilized construction entrance, discharge point silt fence sediment containment, and an earthen berm at toe of slope to prevent runoff and allow stormwater to pond and infiltrate onsite. No BMP violations or issues observed at this time.
Random Inspection10/2/201410/2/201410/2/2014PPASS
DetailsAndy J. Long
Grading at RH #6 has been done in such a way that stormwater from upper portion of site is contained by a berm to prevent discharge to Warm Springs.

Construction entrance installed and in use, silt fence along areas of potential runoff on Warm Springs. Permit and SWPPP info clearly posted. Approved.
Random Inspection9/11/20149/11/20149/11/2014APASS
DetailsAndy J. Long
River Heights # 6 has started with clearing and preliminary grading complete. Since starting no complaints received; no dust or trackout issues observed.

Stationary water tank is located on site; permits posted.
Conference8/28/20148/28/20148/28/2014PDONE
DetailsAndy J. Long
River Heights Sub # 6 Pre-construction meeting with developers, contractors, and Public Works engineers.

BMPs previously installed. Discussed ESC permit conditions and exchanged contact information for Laser Leveling and Nampa Excavation forement.
Site Preparation8/22/20148/22/20148/22/2014PPASS
DetailsAndy J. Long
Site preparation for River Heights #6. Inspection requested by Brighton Corp. RP Daniel.



Met RP on site to review SWPPP and ESC site map. BMPs for the first phase (rough grading) are installed. The construction entrance will be installed next week once the rough grading begins by Nampa Paving.

Sheet flow from upper end of development flows toward existing. A wattle has been lined against the wood fence that has been installed.

Permit and NOI posted.

Approved. Construction will begin next week once GRD permit is released.
Site Preparation8/22/20148/22/20148/22/2014PCANC
DetailsAndy J. Long
Check for BMP installation. Review SWPPP on site.
General Inspection1/16/20171/16/2017   
DetailsMelissa Jannusch