Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberESC15-00178
StatusFinaled
Name SAM INGRAM
Site Address 3555 N MILWAUKEE ST
Project NameValley View Parking lot
Customer Number 
ePlanReviewNo
Description
Elementary school parking lot reconfiguration, removal of existing asphalt, curbing and landscaping. Excavate abandoned septic tank. Will install new bus turnaround, parking spaces, and landscaping. No surface waters receive storm water from project area. No offsite discharge to MS4. BMPs to protect existing and new drainage facitilities, permiter sediment control (fiber wattles), stabilized entrance to prevent trackout, and responsibility to control fugitive dust. Vegetative and nonvegetative stabilization of disturbed area. Will need designated and leakproof concrete washout. SWPPP and ESC plan designed for contractor yet to be determined. SWPPP controls also cover installation of modular classroom (see BLD15-00412)
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection10/27/201510/27/201510/27/2015 PASS
DetailsEvan Jenkins
DOC - Permit Finaled10/27/201510/27/201510/27/2015PPASS
DetailsEvan Jenkins
Project Complete
ESC Conditions Satisfied
General Inspection8/26/20158/26/20158/26/2015 PASS
DetailsEvan Jenkins
WIP: on landscaping/sidewalks
no issues observed
General Inspection6/26/20156/26/20156/26/2015PPART
DetailsAndy J. Long
Work already started early June. No site prep conducted. No violations at site, BMPs installed.