Permit Information
Permit NumberESC15-00403
StatusFinaled
Name ROB HADDOCK
Site Address 3000 S BOWN WAY
Project NameRiverwalk Condos at Bown Cross
Customer Number 
ePlanReviewNo
Description
10 Unit Apartment complex with surface parking on existing parking area.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final4/13/20174/13/20174/13/2017PPASS
DetailsMelissa Jannusch
General Inspection4/13/20174/13/20174/13/2017 PASS
DetailsMelissa Jannusch
Dirt pile and trash in parking lot have been cleaned okay to final
General Inspection3/29/20173/29/20173/29/2017 PASS
DetailsMelissa Jannusch
Library nearing completion. Sidewalk and curb work complete. Soil not yet stabilized. No corrections requested.
General Inspection3/14/20173/14/20173/14/2017 PASS
DetailsMelissa Jannusch
To obtain ESC site final need to remove small dirt pile in corner of parking lot and trash.
General Inspection2/27/20172/27/20172/27/2017 PASS
DetailsAndy J. Long
Project near completion. Building exterior complete and site landscaping and permanent stormwater swale are installed. No offsite discharges, no trackout or loose trash around site perimeter. WIP on installing carports in parking lot with some disturbed area that need stabilization and final sweep up before ESC site final.
General Inspection2/10/20172/10/20172/10/2017 PASS
DetailsMelissa Jannusch
Small amount of work in parking lot. Small amount of trackout. Make sure this is cleaned before final. Surrounding vegetation is mature.
General Inspection1/26/20171/26/20171/27/2017 CANC
DetailsAndy J. Long
General Inspection1/11/20171/11/20171/12/2017 CANC
DetailsAndy J. Long
General Inspection12/27/201612/27/201612/28/2016 CANC
DetailsAndy J. Long
General Inspection12/12/201612/12/201612/13/2016 CANC
DetailsAndy J. Long
General Inspection11/25/201611/25/201611/25/2016 CANC
DetailsAndy J. Long
General Inspection11/10/201611/10/201611/10/2016 CANC
DetailsAndy J. Long
General Inspection10/26/201610/26/201610/27/2016 PASS
DetailsAndy J. Long
WIP on exterior finish and interior. Loose dirt in guttter on Bown has been removed/cleaned. No new trackout or issues.
General Inspection10/11/201610/11/201610/11/2016 PASS
DetailsPhil Shearer
No trackout, discharges, or uncontained trash observed
General Inspection9/26/20169/26/20169/26/2016 CANC
DetailsAndy J. Long
General Inspection9/9/20169/9/20169/9/2016 PASS
DetailsAndy J. Long
WIP. Structure is framed. Exterior and interior finishes occuring. Vegetation around site has been preserved, site storm water retention system is already installed. No trackout, discharges, or uncontained trash observed.
General Inspection8/25/20168/25/20168/25/2016 PASS
DetailsAndy J. Long
General Inspection8/10/20168/10/20168/10/2016 PASS
DetailsAndy J. Long
WIP. Vertical construction, no earthwork or utility installation remaining except final landscaping. No trackout or loose dirt/sediment leaving site.
General Inspection7/26/20167/26/20167/26/2016 PASS
DetailsAndy J. Long
General Inspection7/11/20167/11/20167/12/2016 PASS
DetailsAndy J. Long
General Inspection6/24/20166/24/20166/24/2016 PASS
DetailsAndy J. Long
Vertical construction in progress. No earthwork. No violations observed.
General Inspection6/9/20166/9/20166/10/2016 PASS
DetailsAndy J. Long
No trackout. Vegetated perimeter is undisturbed. Working on the interior. Site infrastructure already installed.
General Inspection5/25/20165/25/20165/25/2016 PASS
DetailsAndy J. Long
WIP. No trackout or discharges. Vegetated swale at corner of Bown and Parkcenter is undisturbed and berm keeps out sediment during rain. Construction fencing defines site limits. No corrections issued.
General Inspection5/10/20165/10/20165/10/2016 PART
DetailsEvan Jenkins
WIP: sweep minor trackout off road
General Inspection4/25/20164/25/20164/25/2016 PASS
DetailsEvan Jenkins
WIP: no ESC issues at this time
General Inspection4/8/20164/8/20164/8/2016 PASS
DetailsAndy J. Long
No trackout or sediment/debris leaving site. No activity at time of inspection. No violations.
General Inspection3/24/20163/24/20163/24/2016 CANC
DetailsAndy J. Long
General Inspection3/9/20163/9/20163/10/2016 CANC
DetailsAndy J. Long
General Inspection2/23/20162/23/20162/24/2016 PART
DetailsAndy J. Long
No activity at site. No discharges or trackout.

Corrections needed at site:

- remove damaged and inoperable silt fence
- clean loose trash around site
- sweeping parking lot/staging area

Correction issue to Travis with Pinnacle Builders.
General Inspection2/8/20162/8/20162/8/2016 PART
DetailsAndy J. Long
Corrections needed:

- post ESC permit sign
- sweep up parking lot/staging area

General Inspection1/21/20161/22/20161/22/2016PPART
DetailsAndy J. Long
Vertical construction in progress. No earthwork occuring. Need to repair silt fence barrier or install alternative perimeter control. No trackout or discharges observed.
General Inspection1/21/20161/22/20161/21/2016ACANC
DetailsAndy J. Long
data entry error
General Inspection1/21/20161/21/20161/21/2016 CANC
DetailsAndy J. Long
General Inspection1/6/20161/6/20161/6/2016 PASS
DetailsAndy J. Long
WIP on first floor columns and site work. No earth work. Site perimeter is stabile, no muddy runoff discharges observed.
General Inspection12/22/201512/22/201512/22/2015 PASS
DetailsAndy J. Long
No activity at site. Seems to be inactive for over 1 month. Site security fence has been knocked down.

No trackout or discharges occuring, water retained within foundation footprint.
General Inspection12/3/201512/4/201512/7/2015ACANC
DetailsAndy J. Long
General Inspection12/3/201512/3/201512/3/2015 CANC
DetailsAndy J. Long
rescheduled for 12/4
General Inspection11/18/201511/18/201511/18/2015 PASS
DetailsAndy J. Long
No construction activity at time of inpsection. Foundation was recently poured and a lined concrete washout box (Outpack) was utilized. No spills or leaks.

Site staging/parking area is utilizing existing paved area so no trackout issues. Silt fence installed along Bown Street is keeping west side of project contained. No activity in the swale overflow channel area next to Greenbelt with no loose sediment or disturbed area in channel. Site utilities are now installed so dewatering phase is complete and frack tank has been removed.

Permit sign posted, no corrections at this time.
General Inspection10/15/201510/15/201510/15/2015 FAIL
DetailsAndy J. Long
###-#### Rob...

No activity at time of inspection. Warning issued to Hard Rock in regards to not scheduling site prep. Perimeter sediment BMPs and sign are posted. Rain4rent tank on site.

Notified that PW sewer inspector shut the operation down due to dewatering failure.

Dewatering permit pulled with ACHD to discharge "visibly clean and clear water" into MS4 swales.