Permit NumberESC16-00353
StatusIssued
Name CAMERON JAYO
Site Address 750 E NATURE VIEW CT
Project NameSomerset No. 6
Customer Number 
ePlanReviewNo
Description
Extension of existing road in Boise Hills Somerset to add 9 SFH parcels on approximately 4 acres of land. BMPs include designated staging area, construction entrance & trackout controls, sediment filter protection for existing stormwater drop inlets on Pleasant Hill/Nature View, limiting area of disturbance and preserving vegetation as much as possible. After road is installed, new storm drains and graded lots will need erosion and sediment controls installed as indicated on the site map. SWPPP submitted and NOI filed with tracking # IDR12AD95. ESC plan meets City of Boise requirements; pre-construction site preparation inspection and BMP installation required. Call 384-3802 or 794-8996 to schedule inspection. BMPs to be installed per submitted consruction details.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection8/3/20208/3/20208/3/2020 PASS
DetailsMichael Zawacki
Construction has begun on one new home. No issues at site.
General Inspection7/17/20207/17/20207/17/2020 PASS
DetailsMichael Zawacki
No new activity.
Surveyors are at lot staking for future build.
General Inspection7/2/20207/2/20207/2/2020 CANC
DetailsAndy J. Long
General Inspection6/17/20206/17/20206/17/2020 PASS
DetailsMichael Zawacki
No issues from rain event.
General Inspection6/2/20206/2/20206/2/2020 PASS
DetailsMichael Zawacki
No new activity.
General Inspection5/18/20205/18/20205/18/2020 PASS
DetailsMichael Zawacki
Area stable, no new home construction.
General Inspection5/1/20205/1/20205/1/2020 PASS
DetailsMichael Zawacki
General Inspection4/16/20204/16/20204/16/2020 PASS
DetailsMichael Zawacki
No activity, no issues.
General Inspection4/1/20204/1/20204/1/2020 PASS
DetailsMichael Zawacki
No new activity, no issues.
Have seen permit for new home on block.
General Inspection3/17/20203/17/20203/17/2020 PASS
DetailsMichael Zawacki
No new home activity, no esc issues.
General Inspection3/2/20203/2/20203/2/2020 PASS
DetailsMichael Zawacki
General Inspection2/14/20202/14/20202/14/2020 PASS
DetailsMichael Zawacki
General Inspection1/30/20201/30/20201/30/2020 PASS
DetailsMichael Zawacki
No new construction, no failures or issues at any lots.
General Inspection1/15/20201/15/20201/15/2020 PASS
DetailsMichael Zawacki
No new building activity, site is frozen and snow covered.
General Inspection12/31/201912/31/201912/31/2019 PASS
DetailsMichael Zawacki
General Inspection12/16/201912/16/201912/16/2019 PASS
DetailsMichael Zawacki
No issues at site.
General Inspection11/29/201911/29/201911/29/2019 CANC
DetailsAndy J. Long
General Inspection11/14/201911/14/201911/15/2019 PASS
DetailsMichael Zawacki
No new activity.
General Inspection10/30/201910/30/201910/30/2019 PASS
DetailsMichael Zawacki
No new activity. Home lots are stable. Built homes are stable.
General Inspection10/15/201910/15/201910/15/2019 CANC
DetailsAndy J. Long
General Inspection9/30/20199/30/20199/30/2019 PASS
DetailsMichael Zawacki
No new activity.
General Inspection9/13/20199/13/20199/13/2019 PASS
DetailsMichael Zawacki
No new activity
General Inspection8/29/20198/29/20198/29/2019 PASS
DetailsMichael Zawacki
General Inspection8/14/20198/14/20198/14/2019 PASS
DetailsMichael Zawacki
No new activity.
General Inspection7/30/20197/30/20197/30/2019 PASS
DetailsMichael Zawacki
No new activity, no ESC issues.
General Inspection7/15/20197/15/20197/15/2019 PASS
DetailsMichael Zawacki
No new activity, lots are stable.
General Inspection6/28/20196/28/20196/28/2019 PASS
DetailsMichael Zawacki
No new activity, BMPs in place.
General Inspection6/13/20196/13/20196/13/2019 PASS
DetailsMichael Zawacki
No new homes, no esc issues.
General Inspection5/29/20195/29/20195/29/2019PPASS
DetailsMichael Zawacki
No major ESC issues, lots were able to hold the water.
General Inspection5/24/20195/24/20195/24/2019 PASS
DetailsMichael Zawacki
No new construction activity. Sidewalks have been swept, new wattle placed across driveway entrances.
General Inspection5/9/20195/9/20195/16/2019 FAIL
DetailsAndy J. Long
No BMP maintenance has occured as requested.

Second request sent to developer/RP to provide sidewalk sweep up and repair/refresh BMPs on open lots.
General Inspection4/24/20194/24/20194/25/2019 PART
DetailsAndy J. Long
Wattles and berms on vacant lots need maintenance. No significant failures or eroded slopes observed.

Sediment runoff of evidence of erosion on lot 4 at top left of street needs to be cleaned up and additional controls installed.

Empty out storm drain sediment bags at bottom hill @ Club View/Pleasant HIll.

RP Cameron notifed
General Inspection4/9/20194/9/20194/9/2019 PASS
DetailsMichael Zawacki
No new activity.
General Inspection3/25/20193/25/20193/25/2019 PASS
DetailsMichael Zawacki
No new activity. BMPs are nearing the end of their usefull life.
General Inspection3/8/20193/8/20193/8/2019 CANC
DetailsAndy J. Long
General Inspection2/21/20192/21/20192/26/2019 PASS
DetailsMichael Zawacki
No new construction activity on any lots.
General Inspection2/6/20192/6/20192/6/2019 FAIL
DetailsMichael Zawacki
BMPs over driveways are starting to fail, dirt running onto street and sidewalks.
General Inspection1/21/20191/21/20191/22/2019 PASS
DetailsMichael Zawacki
No new building activity. BMPs are in rough shape and still working.
General Inspection1/4/20191/4/20191/4/2019 CANC
DetailsAndy J. Long
General Inspection12/20/201812/20/201812/20/2018 PART
DetailsMichael Zawacki
Snow melt and rain eroded into prepped area for landscaping, needs repairs.
General Inspection12/5/201812/5/201812/10/2018 PASS
DetailsMichael Zawacki
No new activity.
General Inspection11/20/201811/20/201811/20/2018 PASS
DetailsMichael Zawacki
No new home or construction activity. Vacant lots have wattle perimeter, wattle is getting old and sections may fail during rain event.
Currently site is clean.
General Inspection11/5/201811/5/201811/5/2018 PASS
DetailsMichael Zawacki
No new activity.
General Inspection10/19/201810/19/201810/19/2018PPART
DetailsMichael Zawacki
No new activity on any of the lots. Sidewalks have dirt from runoff from driveway locations. Gator guard at drives should be replaced, it is flat from being ran over.
General Inspection10/19/201810/19/201810/19/2018 CANC
DetailsMichael Zawacki
Data entry error
General Inspection10/4/201810/4/201810/4/2018 PASS
DetailsMichael Zawacki
Lots are contained, no runoff.
General Inspection9/19/20189/19/20189/19/2018 PASS
DetailsMichael Zawacki
No new activity on any of the building lots.
General Inspection9/4/20189/4/20189/4/2018 PASS
DetailsMichael Zawacki
No new activity, no runoff from any lots.
General Inspection8/20/20188/20/20188/20/2018 FAIL
DetailsMichael Zawacki
No homes currently under construction. Building waste and old washout is on a few of the lots. Some runoff onto road and sidewalk from lower homes irragation. Site will need washout for next homes being built. Sand has ran down to Pleasant Hill, one witches hat has blown out, the other is nearly full.
General Inspection8/3/20188/3/20188/3/2018 PEND
DetailsAndy J. Long
Two SFHs complete.

Developer or new builder will need to install new DI bag on Clubview.
Random Inspection7/19/20187/19/20187/19/2018PFAIL
DetailsAndy J. Long
Corrections needed:

Need to replace sediment protection on receiving storm drains on Club View.

Vebal correction request to Jayo (subdivision developer)
General Inspection7/12/20187/12/20187/12/2018 PASS
DetailsMichael Zawacki
1 home in progress. No esc issues.
General Inspection6/27/20186/27/20186/27/2018 PASS
DetailsMichael Zawacki
Some dirt on road, shows signs of being swept. All materials are stored on vacant lots, two homes in area.
General Inspection6/12/20186/12/20186/12/2018 PART
DetailsMichael Zawacki
Some runoff onto sidewalks from a few sites. Area can use a sweeping. Old washout has been dumped on vacant lots, shoulde be scraped up and removed.
General Inspection5/28/20185/28/20185/29/2018 PASS
DetailsMichael Zawacki
Some small area of runoff onto sidewalk. Talked to RP on site.
General Inspection5/11/20185/11/20185/11/2018 PASS
DetailsMichael Zawacki
Sites are not causing any runoff onto road.
General Inspection4/26/20184/26/20184/26/2018 PASS
DetailsMichael Zawacki
Neighborhood BMPs in place. One lot is mess. Inlets at Pleasant Hill need to be cleaned.
General Inspection4/11/20184/11/20184/11/2018 PASS
DetailsMichael Zawacki
WIP on homesites. Lots are stabalized. Lots of sand is at bottom of hill.
General Inspection3/27/20183/27/20183/27/2018 FAIL
DetailsMichael Zawacki
Lots of sand in the north side gutter. Sand is coming from lot on bottom of hill, rill forming from graded level down drive and onto sidewalk and road.
General Inspection3/12/20183/12/20183/12/2018 PART
DetailsMichael Zawacki
Each lot has its own perimeter controls. Inlets on Pleasant Hill need to be cleaned. Lots of sand at the intersection of Nature View and Pleasant Hill
General Inspection2/23/20182/23/20182/26/2018 PEND
DetailsMichael Zawacki
Snow covered. Can't tell if last issues have been resolved.
General Inspection2/8/20182/8/20182/8/2018 PART
DetailsMichael Zawacki
Lots of trackout from 864 onto Nature View Ct. DI bags on Pleasant Hill need to be cleaned.
General Inspection1/24/20181/24/20181/24/2018 PASS
DetailsMichael Zawacki
Each homesite has their own BMPs. Some trackout in area where workers are present. No runoff down road. DIs are protected and maintained.
General Inspection1/9/20181/9/20181/9/2018 PART
DetailsMichael Zawacki
WIP on SFH. Some trackout from a few homes, all workers now parking on street. Neighborhood BMPs in place, some of the gator guard is wearing out. No muddy runoff coming from home sites. There is a bit of sand and dirt in the gutters and on the road, combination from sanding from plows and dirt from site. Streets can use a pass by a sweeper. DIs at bottom of hill need to be maintained, full of leaves and debris.
General Inspection12/25/201712/25/201712/26/2017 PASS
DetailsMichael Zawacki
WIP on SFH. BMPS installed, currently under snow. Active sites are clean and free of trash.
General Inspection12/8/201712/8/201712/8/2017 FAIL
DetailsMichael Zawacki
DIs at bottom of hill full of leafs, lots of sand in the gutter.
Significant trackout throughout project site.
General Inspection11/23/201711/23/201711/24/2017 PASS
DetailsMichael Zawacki
Each lot has its own perimeter controls. No dirt leaving lots, road and sidewalks clean.
General Inspection11/8/201711/8/201711/8/2017 PEND
DetailsMichael Zawacki
Wip on homes. Lots are protected and street free from runoff. Washout in use but doesn't look lioned. Lots of sand on road at bottom of hill, intersection of Pleasant Hill.
General Inspection10/24/201710/24/201710/24/2017 PASS
DetailsMichael Zawacki
Controls in place, Dis at bottom of hill full of debris, called RP and asked for them to be cleaned.
General Inspection10/9/201710/9/201710/10/2017 PASS
DetailsMichael Zawacki
wattle and gator guard used as perimeter protection. Current buildings also have silt fence.Minimal trackout, each lot is protected at entrance. DIs at Pleasant Hill are filling with leaves.
General Inspection9/22/20179/22/20179/22/2017PPASS
DetailsAndy J. Long
Subdivision BMPs installed. No muddy runoff or trackout. 2 SFHs in progress with ESC permits.
General Inspection9/19/20179/19/20179/22/2017PCANC
DetailsAndy J. Long
General Inspection9/13/20179/13/20179/19/2017 CANC
DetailsAndy J. Long
General Inspection8/29/20178/29/20178/30/2017 CANC
DetailsAndy J. Long
General Inspection8/11/20178/14/20178/18/2017APEND
DetailsAndy J. Long
WIP on one SFH, subdivision BMPs installed. No violations or issues observed.

Still working on the placement of backfill at top of Ridgeline and the eroded gully there.
General Inspection8/7/20178/7/20178/11/2017 CANC
DetailsAndy J. Long
General Inspection7/21/20177/21/20177/21/2017 PASS
DetailsAndy J. Long
General Inspection7/6/20177/6/20177/6/2017APASS
DetailsAndy J. Long
No activity. NO hillside erosion, sediment runoff, or other violations observed. Approved.
General Inspection6/22/20176/22/20176/22/2017 CANC
DetailsMelissa Jannusch
General Inspection6/7/20176/7/20176/7/2017 PASS
DetailsMelissa Jannusch
No WIP. BMPs okay. No corrections.
General Inspection5/23/20175/23/20175/23/2017 PASS
DetailsMelissa Jannusch
Site inactive. No ESC issues.
General Inspection5/8/20175/8/20175/9/2017 PASS
DetailsMelissa Jannusch
No WIP. All BMPs are in place and ok.
General Inspection4/21/20174/21/20174/21/2017 PASS
DetailsAndy J. Long
No activity. Perimeter wattles along lots are installed. No significant hillside erosion observed. Storm drains have inlet protection. Approved
General Inspection4/6/20174/6/20174/6/2017 PASS
DetailsMelissa Jannusch
Project inactive. BMPs oks. No corrections
General Inspection3/22/20173/22/20173/22/2017 PASS
DetailsMelissa Jannusch
Project okay. No WIP. Concrete washout has been installed.
General Inspection3/7/20173/7/20173/7/2017PPASS
DetailsMelissa Jannusch
General Inspection2/21/20172/21/20172/22/2017 PASS
DetailsMelissa Jannusch
No corrections requested
General Inspection2/6/20172/6/20172/6/2017 PART
DetailsMelissa Jannusch
SWPPP and permit sign are visible. Subdivision BMPs are in place. No current WIP. Gatergaurds are working effectively at preventing runoff from lot entry ways. No trackout.

Correction Requested: There is rill erosion occurring on the west side of the sidewalk about half way up the road. Which is depositing a good amount of soil onto the sidewalk. Left message with Cameron Jayo requesting additional BMPs in the problem area to slow water and sediment, and requested cleanup of the soil on the sidewalk.
General Inspection1/19/20171/19/20171/19/2017PPASS
DetailsMelissa Jannusch
No activity. Snow covered conditions. No muddy run off.
General Inspection1/5/20171/9/20171/17/2017PCANC
DetailsAndy J. Long
General Inspection1/5/20171/5/20171/5/2017 CANC
DetailsAndy J. Long
General Inspection12/21/201612/21/201612/21/2016 CANC
DetailsAndy J. Long
General Inspection12/6/201612/6/201612/9/2016 CANC
DetailsAndy J. Long
General Inspection11/18/201611/21/201611/25/2016APASS
DetailsBen Livingston
no new activity,
General Inspection11/18/201611/18/201611/18/2016 CANC
DetailsAndy J. Long
rescheduled for 11/21
General Inspection11/3/201611/3/201611/3/2016 PASS
DetailsDaryl Spivey
No activity at this time. site clean and bmp's in place.
Random Inspection10/18/201610/18/201610/18/2016PPASS
DetailsAndy J. Long
No issues observed due to rainfall on recently developed foothills sub. BMPs installed and preveting muddy runoff. No corrections requested.
General Inspection10/12/201610/12/201610/12/2016PPASS
DetailsAndy J. Long
No recent activity, no construction materials or stockpiles on site. Hillside BMPs installed. Entrances to parcels have gator guard wattles and have berms installed to contain and direct runoff away from sloped banks between terraced lots. Storm drain has sediment filter bag, hillsides have some vegetation. No corrections at this time.
General Inspection9/21/20169/22/20169/22/2016APASS
DetailsAndy J. Long
General Inspection9/21/20169/21/20169/21/2016 CANC
DetailsAndy J. Long
rescheduled for 9/22
General Inspection8/25/20168/25/20168/25/2016PPART
DetailsAndy J. Long
Road is now paved and permanent stormwater system is installed. DIs on Clubview/Pleasant Hill are have filter bags. No runoff from lots, slopes between lots have wattles.


Verbal correction request to RP:

Sweep up some curb cutting died slurry dust in the gutter at bottom of Nature View CT on uphill side of road.
General Inspection7/29/20167/29/20167/29/2016PPASS
DetailsAndy J. Long
Crew on site preping road base for Nature View extension into Somerset Ridge #6. Receiving storm water gutter and drain has sediment protection. Water truck on site for compaction and dust control as needed. No dust issues at time of inspection. No trackout to Clubview, no discharges. Approved.
General Inspection6/24/20166/24/20166/24/2016PPASS
DetailsAndy J. Long
United Water recently installed water lines. No activity at time of inspection. Hillside sediment control wattles are installed and mostly trenched in. Rock construction entrance installed and permit sign posted with SWPPP info.

No corrections requested. Hillsides between parces have been tracked and some are vegetating on their own.
Random Inspection5/25/20165/25/20165/25/2016PPASS
DetailsEvan Jenkins
Random Inspection

WIP: No ESC issues observed at this time
General Inspection5/19/20165/19/20165/19/2016PPASS
DetailsAndy J. Long
Road footprint and parcels have been graded. Temporary sediment control wattles have been installed. The has been no hydomulching or tacifier applied at this point.

Permit sign posted with eNOI, SWPPP information in mail box.

No trackout or evidence of sediment discharges, BMPs are working. Approved.
Random Inspection4/26/20164/26/20164/26/2016PPASS
DetailsAndy J. Long
WIP on grading and parcel prep at Somerset phase 6. BMPs are installed including DI bags, slope and perimter wattles and regular sweeping. No trackout, erosion, dust, or other issues observed. Site is in compliance.
General Inspection4/13/20164/13/20164/14/2016PPASS
DetailsAndy J. Long
WIP on new Somerset phase. Construction entrance, DI bags, and permit/swppp information are installed and in good condition.

Crew is installing ESC controls as they work up the slope. No corrections needed at this time.
Site Preparation4/4/20164/5/20164/5/2016APASS
DetailsAndy J. Long
Somerset #6 10 AM site preparation inspection & pre-construction conference

Pre-construction conference with engineers, plan designer, developer, and operator. BMPs to be installed in phases as the excavation works up the hill. Once initial grading is accomplished around the entrance, a construction entrance for trackout prevention will be installed. Perimeter wattles at the bottom of site will be installed this week prior to excavation. Plan is to preserve existing vegetation on parcels as much as possible. DIs on Pleasant Hill have sediment bag protection.

SWPPP, ESC permit sign and NOI posted at site ,CGP tracking # IDR12AD95

Approved for construction.