Permit Information
Permit NumberESC16-00941
StatusFinaled
Name DAVE ONEAL
Site Address 3572 E GRAND FOREST DR
Project NameHeavenwood
Customer Number 
ePlanReviewNo
Description
Construction of 11 new multifamily buildings-4 building types for a total of 48 units. Project includes site development
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection9/25/20189/25/20189/25/2018 CANC
DetailsMichael Zawacki
DOC - Permit Finaled9/25/20189/25/20189/25/2018PPASS
DetailsMichael Zawacki
General Inspection8/10/20188/10/20188/10/2018PPASS
DetailsAndy J. Long
WIP on landscaping common areas. All parking areas and access to Havenwood is complete. No trackout, fugitive dust or other issues. Minimal activity at time of inspection.
General Inspection7/10/20187/10/20187/10/2018 PASS
DetailsMichael Zawacki
All buildings complete, work is interior. Site has started to be landscaped, stll lots of exposure. No ESC issues.
General Inspection5/25/20185/25/20185/25/2018 CANC
DetailsAndy J. Long
General Inspection4/9/20184/9/20184/9/2018 PASS
DetailsMichael Zawacki
Landscape and irrigation work in process. Site is all paved and curb and gutter in place, No ESC issues. Some wattle in ditch can now be removed. Landscaping will remove old silt fence as they progress.
General Inspection2/20/20182/20/20182/21/2018PPASS
DetailsMichael Zawacki
Parking lots paved and most sidewalks complete. Area still needs to be landscaped. Building work is now interior, no trash or building waste laying around. Silt fence will be removed as landscapers reach areas.
General Inspection1/22/20181/23/20181/23/2018PPASS
DetailsMichael Zawacki
Work on exteriors, sidewalk, and pavement complete. Landscapers will start soon and remove BMPs as they go. DIs around area still protected. No issues with run off.
General Inspection1/16/20181/17/20181/22/2018ACANC
DetailsAndy J. Long
General Inspection1/15/20181/15/20181/16/2018 CANC
DetailsAndy J. Long
General Inspection11/28/201711/28/201711/28/2017PPASS
DetailsMichael Zawacki
Inspected 11-24. No changes
General Inspection11/24/201711/24/201711/24/2017 PASS
DetailsMichael Zawacki
WIP on interiors. No dirt leaving property. All trash contained and site is paved and free of track out.
General Inspection10/9/201710/9/201710/12/2017 PASS
DetailsMichael Zawacki
Job trailer was locked, unable to view SWPPP book. Site has been freshly paved, no trackout. Multiple containers for trash being used. DIs all protected. Work areas appear clean and well maintained. Perimeter controls intact.
General Inspection8/22/20178/24/20178/25/2017PCANC
DetailsAndy J. Long
General Inspection8/22/20178/22/20178/22/2017 CANC
DetailsAndy J. Long
General Inspection7/7/20177/7/20177/7/2017 PASS
DetailsMelissa Jannusch
General Inspection5/22/20175/22/20175/22/2017 PASS
DetailsMelissa Jannusch
No trackout. Trash contained. SWPPP not available on site. Perimeter controls are ok. Talked with onsite representative about making sure SWPPP was on site and that regular inspection were occurring. No corrections.
General Inspection4/6/20174/6/20174/6/2017 CANC
DetailsMelissa Jannusch
General Inspection2/15/20172/15/20172/15/2017 PASS
DetailsMelissa Jannusch
No corrections requested
General Inspection11/25/201611/25/201611/25/2016APASS
DetailsAndy J. Long
WIP. No significant trackout. Perimeter silt fence installed. Foundation work of apartment buildings has started. No activity at time of inspection.
General Inspection10/24/201610/24/201610/24/2016PPASS
DetailsAndy J. Long
WIP on apartment subdivision grading, storm water, and infrastructure. Silt fence perimter installed, no trackout to existing paved parking lot.

Work by landscaping crew for irrigation line re-location is complete and stabilized.

Approved.
General Inspection10/21/201610/21/201610/24/2016PCANC
DetailsAndy J. Long
see 10/24
General Inspection9/19/20169/19/20169/19/2016PPART
DetailsAndy J. Long
check into work reported in existing swale previously protected by silt fence.

Columbia Village subdivision has hired Aloha Landscaping to dig up and re-install their 4" irrigation line that was initial placed in the wrong location and on private property (Havenwood)

Notified RP that Aloha would need to re-install and replace broken silt fence. Sweep up in swale. Will follow up with Aloha Landscaping as well.

Correction to Havenwood RP:
- Install correct rock construction entrance per construction details on SWPPP plan
General Inspection8/30/20169/8/20169/7/2016APASS
DetailsAndy J. Long
check for remaining BMP installations and dust control

Permit sign posted. Dust suppression water being used during active grading. No plumes visible. Construction entrance rock is onsite for installation. No trackout. Silt fence perimeter and chain link fence are in excellent condition.
Site Preparation8/26/20168/30/20168/30/2016PPASS
DetailsAndy J. Long
3 PM w/ Dave ###-####

Site walk through performed with RP and site supervisor for initial excavation and utility work. Reviewed SWPPP map and installation of perimeter sediment control silt fence. Site will have two rock construction entrances that are not yet installed. Reviewed rules regarding trackout and cement washout containment.

Water truck is already onsite for dust control. Chainlink fencing will enclose the site.

Approved for construciton. Will follow up next week to check on initial work and BMP conditions.