General Inspection | 8/31/2017 | 8/31/2017 | 8/31/2017 | P | PASS |
Andy J. Long
|
|
|
project now covered under ESC16-01292. No violations. Permit finaled.
|
DOC - Permit Finaled | 8/31/2017 | 8/31/2017 | 8/31/2017 | P | PASS |
Andy J. Long
|
|
|
|
General Inspection | 7/12/2017 | 7/12/2017 | 7/12/2017 | P | PASS |
Melissa Jannusch
|
|
|
WIP on excavation. SCE is maintained. No trackout. Evidnece of recent water truck activity. No dust observed during inspection. No corrections issued.
|
General Inspection | 6/29/2017 | 6/29/2017 | 6/30/2017 | P | PASS |
Melissa Jannusch
|
|
|
WIP on excavation and grading. No fugitive dust observed but water truck should be used if dust becomes an issue. No corrections issued.
|
BMP Violation | 5/15/2017 | 5/18/2017 | 5/19/2017 | P | PASS |
Melissa Jannusch
|
|
|
SIgn is posted and some rock has been added to entrance. No WIP
|
General Inspection | 5/15/2017 | 5/15/2017 | 5/15/2017 | P | FAIL |
Melissa Jannusch
|
|
|
No permit or SWPPP sign posted. Construction entrance needs maintenance. Called RP and left a message requesting that SWPPP sign with City of Boise permit sign be posted and construction entrance be maintained by Thursday. Need to protect culverts in drainage channel and preform dust control as needed.
|
Aging Inspection | 5/12/2017 | 5/12/2017 | 5/12/2017 | | CANC |
Melissa Jannusch
|
|
|
|
General Inspection | 3/10/2017 | 3/13/2017 | 3/13/2017 | P | PASS |
Andy J. Long
|
|
|
No new activity or construction at site. No trackout, permit sign posted next to rock construction entrance.
Whe construction resumes, need to request sediment controls to protect culvert pipe under S. Broadway along west side of site.
|
General Inspection | 3/8/2017 | 3/8/2017 | 3/10/2017 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 11/25/2016 | 11/25/2016 | 11/25/2016 | A | PART |
Andy J. Long
|
|
|
Site rough grading has been completed, project inactive. No ground cover or stabilization but periodic dust suppression watering has occured. No wind blown or fugitve dust issues observed or reported. Permit sign and construction entrance installed. No trackout or uncontained waste materials.
Correction request - - install check dams on the onsite shoulder borrow ditch to prevent culvert pipe from clogging
|
BMP Violation | 9/8/2016 | 9/9/2016 | 9/9/2016 | P | PASS |
Andy J. Long
|
|
|
1 PM compliance inspection. Complaint of no sign or BMPs received on 9/8.
Permit sign is now posted and construction entrance is installed as requested. Site meeting to be conducted next week with RP MIke to discuss dust control. No dust blowing during light wind at time of inspection.
Possible solutions are : - Install windscreen/privacy fence - flatten tops of the stockpiles onsite - daily application of water via water
There is a culvert that drains the roadside ditch. Will request some check dams leading up to culvert to prevent it from being clogged
note: EPA tracking # IDR12AJ48
|
BMP Violation | 9/8/2016 | 9/9/2016 | 9/9/2016 | P | CANC |
Andy J. Long
|
|
|
1 PM
|
General Inspection | 8/26/2016 | 8/26/2016 | 8/26/2016 | P | PART |
Andy J. Long
|
|
|
Reviewed ESC permit conditions and posting requirements. In particular the requirement to make a practicable effort at fugitive dust control during active construction. It is evident a water truck has been on site.
Mike will post permit information this weekend and wil ensure water truck is available for work. He notified me this will be a slow moving project at the beginning.
|
General Inspection | 8/22/2016 | 8/22/2016 | 8/22/2016 | P | FAIL |
Andy J. Long
|
|
|
Need to post ESC permit sign. No site prep inspection requested as required.
No activity at site, but report of grading conducted without dust control
|
General Inspection | 8/12/2016 | 8/12/2016 | 8/12/2016 | P | CANC |
Evan Jenkins
|
|
|
|