Permit Information
Permit NumberESC16-01446
StatusFinaled
Name SCOTT PAGE
Site Address 348 S 13TH ST
Project NameBOISE HILTON GARDEN INN
Customer Number 
ePlanReviewNo
Description
5 story wood framed 132 unit hotel building within Pioneer Crossing development area. Project on north west corner of Parcel B, see ESC16-01354 for Pioneer Crossing project. MS4 inlets around site should have sediment controls installed, controlled trackout prevention construction entrance, and stockpile management. ESC and SWPPP information shall be posted clearly. No NOI tracking # listed at time of plan review
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final8/20/20188/21/20188/21/2018APASS
DetailsAndy J. Long
A exterior areas of disturbance have been stabilized with either hardscape or landscaping. No temporary BMPs left installed or onsite.

ESC permit finaled. BLD is temp. occupancy and GRD is open.
Site Final7/16/20187/17/20187/17/2018PNR
DetailsAndy J. Long
Please call either myself or Scott at ###-#### when you are on site. We will come and meet with you.

Thanks Phone #: ###-#### Inspection requested via web by David Banks

ESC permit will be ready to final upon completion of paver installation on the NW corner of building and parking lot clean. No temp DI bag removal from MS4 required.

Checking on status to final GRD permit.
General Inspection6/1/20186/1/20186/1/2018 PASS
DetailsMichael Zawacki
Completed all permits as one large site inspection. Controlled entrance and exit, no trackout onto roads. Site is free from fugitive dust, all trash contained. Materials on site are neatly stored. Landscaping along front of hotel not yet completed. Panera Bread has no stucco washout, is being dumped on ground.
General Inspection2/27/20182/27/20182/27/2018 PASS
DetailsAndy J. Long
No trackout or sediment runoff from perimeter. Strom drain inlet protection installed. No corrections requested.
General Inspection12/25/201712/25/201712/26/2017 PASS
DetailsMichael Zawacki
WIP. No issues observed on perimeter walk through. Site is snow covered and frozen. Observations will be made after thaw to watch for exposed dirt and tracking issues.
General Inspection10/16/201710/16/201710/23/2017 CANC
DetailsAndy J. Long
General Inspection8/25/20178/28/20178/31/2017PPASS
DetailsAndy J. Long
NO trackout or discharges. Permit posted. No corrections issued.
General Inspection8/25/20178/25/20178/25/2017 CANC
DetailsAndy J. Long
General Inspection7/10/20177/10/20177/14/2017 CANC
DetailsMelissa Jannusch
General Inspection5/23/20175/23/20175/23/2017PPASS
DetailsAndy J. Long
Vertictal construction in progress. Perimeter curb and gutter installation is near complete. No trackout or discharges observed around perimeter.
General Inspection4/10/20174/10/20174/10/2017APASS
DetailsAndy J. Long
WIP on foundation and flat work. No trackout to to Myrtle or 13th. Permit sign and SWPPP info posted on 13th entrance. MS4 inlets have sediment protection installed. Parcel shared with Pioneer Crossing, see also ESC16-01354..
Tracking Control3/10/20173/13/20173/14/2017PPEND
DetailsAndy J. Long
check for new rock construction entrance out to Myrtle


New rock and sweep up of trackout was performed as requested. Heavy equipment and soft ground and rounded rocks are filling in with mud & dirt quickly - need to provide different type of angular rock material or install rumble bars or asphalt buffer strip in between sidewalk apron and entrance.

RP Chris Stanton (on site) stated a new alternative BMP will be implemented this week as well as re-installing concrete washout facility.
General Inspection3/10/20173/10/20173/10/2017PFAIL
DetailsAndy J. Long
Significant trackout to bike bike lane and traffic lane on Myrtle.

Correction request to RP Chris with Headwaters and Tom with Alta:
- provide new rock to improve muddy construction access
- sweep Myrtle sidewalk, gutter, and north traffic lane to remove trackout and accumulated sediment.

RP stated new rock has now been ordered, Curtis Clean Sweep to sweep Myrtle at the end of the day.

Posted green ESC sign on 13th Street entrance.

Will re-inspect Monday
General Inspection4/16/20184/16/2018   
DetailsMichael Zawacki
General Inspection1/12/20181/12/2018 P 
DetailsMichael Zawacki
General Inspection11/9/201711/9/2017 A 
DetailsMichael Zawacki