Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberESC17-00011
StatusFinaled
Name BOB GOODWIN
Site Address 3625 W ELDER ST
Project NameComfort Inn and Suites - ID077
Customer Number 
ePlanReviewNo
Description
A 108 room, 4-story hotel on a 2.8 acre parcel. BMPs: Stabilized construction entrances (4) one on Elder street and three on the east side of the site, permit signs, DI protection, lined water based waste trench, trash disposal, fiber roll on the south east corner of the site, silt fence as needed (site slopes east to west so potentially on the west side of site). RP TBD.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final8/1/20188/1/20188/1/2018PPASS
DetailsMichael Zawacki
check for temp BMP removal (DI bags on Elder) and clean up/stabilization of adjacent lots used for staging
General Inspection6/18/20186/18/20186/18/2018 PASS
DetailsMichael Zawacki
Exterior building work completed. Landscapers currently on site. No ESC issues. Foreman says they will mow old storage area one more time before they are finished.
General Inspection5/2/20185/2/20185/2/2018PPASS
DetailsMichael Zawacki
Site dirt work and landscaping complete. Currently working on brick facade and interior. Talked to foreman, they are cleaning area as they go, keeping plastic sheeting and styrofoam backer from blowing away. Mortar and stucco is being cleaned from ground as brick work is finished. Multiple dumpsters on site.
General Inspection3/20/20183/20/20183/20/2018PPART
DetailsMichael Zawacki
Southern lot is no longer being used for storage, all storage is now on west end of project. Lots of trackout onto Elder. Site has lots of small pieces of trash and lumber scraps laying around. South side of building is scaffolded and covered with plastic, will need to monitor in wind for being torn off and blowing off site. Perimeter has been landscaped.
General Inspection3/20/20183/20/20183/20/2018PCANC
DetailsAndy J. Long
data entry error
General Inspection2/26/20182/26/20182/26/2018 PASS
DetailsAndy J. Long
Interior work only. No staging or equipment traffic from adjacent open space/former staging area. No corrections requested
General Inspection1/11/20181/11/20181/11/2018PPASS
DetailsMichael Zawacki
Area atround hotel is landscaped and paved. Some trackout onto elder from suppliers picking up materials. Walked site with Tyler and he will get gutters and road cleaned.
General Inspection12/18/201712/18/201712/18/2017 PASS
DetailsMichael Zawacki
Stockpile on south west corner removed. Worker cleaning all the dumped tires off staging area. Perimeter landscaping complete.
General Inspection10/10/201710/31/201711/1/2017APEND
DetailsMichael Zawacki
check on stockpile and stabilization; see if materials have been moved to paved staging areas; check DI bag to see if maintained as requested.
Storage still in vacant lot next to site. Lots of tracking and loose dirt in job area, currently not leaving site. Track Utilities currently doing dirt work. DIs maintained. Stock pile in back appears stable, no dust was present.
General Inspection10/10/201710/10/201710/10/2017PPART
DetailsAndy J. Long
No trackout or discharges. Trash containment onsite is being used.

Correction requests:
- clean gutter and change out DI bag
- provide temporary dust control/water truck for drive road to staging area as well as stockpile.
- once stockpile is removed; initiate temporary or permanent stabilization. RP stated will do hydroseed or fiber mulch.
General Inspection8/31/20178/31/20178/31/2017PPASS
DetailsAndy J. Long
No trackout or fugitive dust observed at time of inspection. Parking lot around hotel footprint is now installed. Using adajacent parcels for frame staging.

Corrections:
- maintenance is needed on DI bags on Elder. RP Bob stated, curb work is finished next week and will sweep street and empty /re-install bags.
- need to clean up unlined washout pit in stockpile area.
- if stockpile continues to be inactive, it will need temporary stabilization with vegetation or cover. RP states that Knife River will begin hauling off stockpile within the next two weeks.
General Inspection7/11/20177/14/20177/14/2017APASS
DetailsMelissa Jannusch
There is significant trackout, due to the wet soil from watering for dust control, but it was already actively being swept up during the time of the inspection. Talked with GC on site and suggested adding angular rocks to the exit rather than round river rocks to help reduce trackout due to watering for dust. No dust observed onsite. Trash is contained. Wattles and DI are in good condition.

General Inspection7/10/20177/11/20177/11/2017APASS
DetailsMelissa Jannusch
Inspection conducted from 9:15 AM to 10:15 AM. When I arrived there was not water truck on site, but the road was still wet from water truck spraying recently (around 9:00 AM).

The RP for the project, Bob, was in the office in Eagle, but he called his onsite foreman who met with me onsite. The foreman said the water truck would be back shortly and generally runs every hour. I suggested when it gets hotter in the afternoon to increase the frequency of watering.

Some sediment is collecting in the gutter from watering the road. Small amount of gravel on the sidewalk. Issued corrections to the foreman onsite.

Corrections requested: 1) Clean up curb line. 2) Sweep up sidewalk.

During the hour of observation there were a 2 dust plumes but the dust did not blow off site to become fugitive dust. The water truck arrived at 10:00AM which is consistent with the every hour of watering schedule. The water on the road from the last pass by the water truck had just finished drying when the water truck returned indicating a good frequency of watering for the site.

Follow up for compliance of corrections requested scheduled for later this week.