Permit Information
Permit NumberESC17-00140
StatusFinaled
Name JUSTIN REYNOLDS
Site Address 404 W SHERMAN ST
Project NameHanrahan Residence
Customer Number 
ePlanReviewNo
Description
As per ESC Conditions. SFH BMPs: stabilized construction entrance, DI bags, fiber rolls along Sherman street
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final6/26/20186/26/20186/26/2018PPASS
DetailsAndy J. Long
Home is now landscaped. No ESC corrections.
General Inspection6/12/20186/12/20186/12/2018 PASS
DetailsMichael Zawacki
Still no landscaping, nothing leavin site.
General Inspection5/28/20185/28/20185/29/2018 PASS
DetailsAndy J. Long
Home complete and occupied. Bond issued for site revegetation, no landscaping completed yet.

No sediment runoff or erosion onsite in front yard observed.
General Inspection5/11/20185/11/20185/11/2018 PASS
DetailsMichael Zawacki
External home construction looks complete. Yard still needs landscaping.
General Inspection4/26/20184/26/20184/27/2018 PASS
DetailsAndy J. Long
General Inspection4/11/20184/11/20184/11/2018 PASS
DetailsMichael Zawacki
Exterior work mostly completed, still some work on back of home. Lot is contained, no runoff.
General Inspection3/27/20183/27/20183/27/2018 PASS
DetailsAndy J. Long
No trackout, no sediment runoff from site. Site is clean.
General Inspection3/12/20183/12/20183/12/2018 PASS
DetailsMichael Zawacki
Owner on site cleaning up front yard. No dirt on street. Lot still needs landscaping.
General Inspection2/23/20182/23/20182/26/2018 PASS
DetailsMichael Zawacki
No workers on site at time of inspection. No issues, working on framing.
General Inspection2/8/20182/8/20182/8/2018 FAIL
DetailsMichael Zawacki
Stucco mixer cleaned and dumped in front lawn. Painting or stucco tools cleaned in backyard.
General Inspection1/24/20181/24/20181/24/2018 PASS
DetailsMichael Zawacki
WIP. House is wrapped and takes up entire lot. No way to get around, scaffolding is blocking side.
General Inspection1/9/20181/9/20181/9/2018 PASS
DetailsMichael Zawacki
WIP. House wrapped in poly. No dirt leaving site.
General Inspection12/25/201712/25/201712/26/2017 PASS
DetailsMichael Zawacki
House takes up majority of yard. No waste out front. Unable to check rear, house wrapped in plastic ans scaffolding on side.
Random Inspection12/8/201712/8/201712/8/2017PPASS
DetailsMichael Zawacki
General Inspection12/8/201712/8/201712/8/2017 PASS
DetailsMichael Zawacki
Not much exposed area. House is majority of lot.
General Inspection11/22/201711/22/201711/22/2017 PASS
DetailsMichael Zawacki
All work currently inside of house. Yard is torn up but secure on lot.
General Inspection11/7/201711/7/201711/7/2017 PASS
DetailsMichael Zawacki
Random Inspection10/19/201710/19/201710/19/2017PCANC
DetailsMichael Zawacki
clean
Site Preparation10/19/201710/19/201710/19/2017PCANC
DetailsMichael Zawacki
BMP Violation9/13/20179/14/20179/19/2017APASS
DetailsAndy J. Long
Oil spill on street has had spill clean up absorbent and sweeping performent. No muddy runoff or trackout. No new corrections.
BMP Violation9/6/20179/6/20179/13/2017PPEND
DetailsAndy J. Long
RP stated crew returned to clean up spill. Investigation/follow up on-going
BMP Violation9/6/20179/6/20179/6/2017AFAIL
DetailsAndy J. Long
Uncontained concrete washout conducted at site.

Oil spill left on roadway with no spill control measures implemented.

Verbal request for immediate cleanup.
General Inspection6/19/20176/19/20176/19/2017PPASS
DetailsMelissa Jannusch
WIP no corrections.
General Inspection5/17/20175/17/20175/17/2017APASS
DetailsAndy J. Long
Excavation is complete. No trackout or sediment runoff observed, wattle re-installed at edge of pavement. Permit posted on power pole. No corrections.