Permit Information
Permit NumberESC17-00375
StatusFinaled
Name ANDY THOMPSON
Site Address 1321 N ETHRIDGE LN
Project NameHollowrose Sub
Customer Number 
ePlanReviewNo
Description
10 lot infill development. BMPs include stabilized construction entrance, concrete washout and trash containment, inlet protection on Etheridge. Fugitive dust controlled required during grading and hauling activity. Need to check for LEW or CGP coverage. Site preparation inspection required.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection10/29/201810/29/201810/29/2018 PASS
DetailsAndy J. Long
All parcels in Hollowrose Sub are now built upon. No subdivision work remaining. SFHs in progress on Maxwell are permitted seperately. No corrections.
DOC - Permit Finaled10/29/201810/29/201810/29/2018PPASS
DetailsAndy J. Long
General Inspection10/12/201810/12/201810/12/2018 PASS
DetailsMichael Zawacki
Last home exterior complete. Lot still needs to be landscaped. No ESC issues.
General Inspection9/27/20189/27/20189/27/2018 PASS
DetailsMichael Zawacki
One home remains under construction. Street shows sign of sweeping.
General Inspection9/12/20189/12/20189/14/2018 CANC
DetailsAndy J. Long
General Inspection8/28/20188/28/20188/28/2018 PASS
DetailsMichael Zawacki
One home remains under construction, the rest are landscaped and only interior remains. Some building material stored on sidewalk.
General Inspection8/13/20188/13/20188/13/2018 PART
DetailsMichael Zawacki
Landscaper has gotten some dirt on sidewalk and road.
Last two foundations poured, washout has been rinsed straight onto ground.
Trackout from recent foundation pours.
General Inspection7/27/20187/27/20187/27/2018 PASS
DetailsAndy J. Long
1 lot under excavation in Hollowrose. Other units near completion. No violations observed.
General Inspection7/12/20187/12/20187/12/2018 PASS
DetailsMichael Zawacki
Project more than half complete. Washout has been dumped on vacant lot on south of project.
BMP Violation6/18/20186/27/20186/29/2018APEND
DetailsAndy J. Long
check for washout clean up
General Inspection6/15/20186/18/20186/18/2018PFAIL
DetailsAndy J. Long
Correction request:

- clean up washout that is full.
- clean up the non-lined washout and provide new portable washout for next project.


Verbal correction request to RP/GC Andy.
General Inspection6/14/20186/14/20186/15/2018 CANC
DetailsAndy J. Long
General Inspection5/18/20185/30/20185/30/2018PPART
DetailsAndy J. Long
check if new washout will be needed. for next round of foundations.

Need new washout, did not overflow but is now full. Need to have excavator sweep up recently excavated foundation. No trackout outside of sub. Trash contained.
General Inspection4/30/20185/16/20185/18/2018PPASS
DetailsAndy J. Long
No trackout or discharges.No earthwork occuring currently, finisih up two homes. No corrections requested.

Will need a new washout for next set of homes. Current washout about 65% full
General Inspection4/27/20184/27/20184/30/2018 PASS
DetailsAndy J. Long
Storm drains have DI bags, concrete washout pit provided. Street and sidewalks are clean. Trash contained. Approved.
BMP Violation4/5/20184/12/20184/13/2018APASS
DetailsMichael Zawacki
Area has been swept, sidewalks and road cleaned. Washout area has been cleaned.
General Inspection4/3/20184/3/20184/5/2018 FAIL
DetailsMichael Zawacki
Entire site is covered with trackout. One concrete washout correctly built, large pile of washout right next to it just dumped on dirt. Site hasn't passed inspection in 2018. Took pictures and will send them to RP. Scheduled follow up for 4/12, if site not improved will hold inspections on other trades until site improved.
General Inspection3/16/20183/19/20183/19/2018PFAIL
DetailsMichael Zawacki
Lots of trackout throughout site. Painters are washing out into the dirt.
General Inspection3/14/20183/14/20183/16/2018 CANC
DetailsAndy J. Long
rescheduled
General Inspection2/27/20182/27/20182/27/2018 PART
DetailsMichael Zawacki
One home has overflowing trash box. Front end loader in use on corner lot causing trackout.
General Inspection2/9/20182/9/20182/9/2018 PART
DetailsMichael Zawacki
Some trackout in neighborhood, not leaving site. Besides trackout site is clean, trash cleaned up.
General Inspection1/24/20181/24/20181/24/2018 PART
DetailsMichael Zawacki
WIP on SFH. All workers parking on paved road. Some piles of scrap lumber that will need to be cleaned. Some trackout, coming from lot posted private and being used for firewood & rough cut lumber storage. No dirt leaving area and DI on ethridge clean and protected.
General Inspection10/23/201710/23/201710/23/2017PPASS
DetailsAndy J. Long
Work complete, parcels have been sold but are not yet active or stabilized. Large stockpile onsite. No discharges, trackout or other violations observed.