Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberESC17-00470
StatusFinaled
Name ROD LUDINGTON
Site Address 11223 W FAIRVIEW AVE
Project NameWILD SHAMROCK
Customer Number 
ePlanReviewNo
Description
ESC plan submitted and approved. Satisfies City of Boise requirements only. No CGP coverage or eNOI identified. Permit covers demolition/relocation, rough grading, utility, and road construction. ESC BMPs include track out control, fugitive dust control, drop inlet protection on Shamrock, and concrete washout for curb and gutter. ESC conference and walk through required.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final10/16/201910/16/201910/16/2019PPASS
DetailsAndy J. Long
lots have vegeatated. Other lots are now occupied with buildings. No further ESC inspections required on this permit.
Aging Inspection10/14/201910/14/201910/14/2019 PASS
DetailsMichael Zawacki
Spoke with foreman of new townhomes. Will keep street clean and have everyone move when curb sweeper comes. Going to try andd get phase 2 poured before winter.
Aging Inspection8/12/20198/12/20198/12/2019 PASS
DetailsMichael Zawacki
Vacant lots are all covered with now dormant vegetation. Apartments being built on sout east parcel, issues are being sent to that sites RP.
Aging Inspection6/10/20196/10/20196/10/2019 PASS
DetailsMichael Zawacki
House has been removed from site. Vacant lots are overgrown. No dust or trackout.
Aging Inspection4/8/20194/8/20194/8/2019 FAIL
DetailsMichael Zawacki
Owner needs to regulate vacant lots. People are driving through mud on site with no activity.
Aging Inspection2/4/20192/4/20192/4/2019 PART
DetailsMichael Zawacki
Rear corner has been leased out for storage. In process of moving out excavator. Some dirt on road, said they will clean it all.
Aging Inspection12/3/201812/3/201812/3/2018 CANC
DetailsAndy J. Long
General Inspection10/1/201810/1/201810/1/2018PPASS
DetailsAndy J. Long
Home on NW corner of development has still not been moved. No new construction activity. No trackout or discahrges from bare lots. No corrections requested. Will continue to monitor.
General Inspection8/6/20188/6/20188/6/2018 PASS
DetailsMichael Zawacki
Vacant lots on south end are stabalized. Bank is nearing completion. Bank workers are parking on lot east of bank and some on road. No issues at site.
General Inspection6/4/20186/4/20186/4/2018 PASS
DetailsMichael Zawacki
Southern lots are overgrown and stable. WIP on bank, nothing leaving site. Workers are parking across street from bank and causing lots of track out. No fugitive dust.
Aging Inspection4/4/20184/4/20184/4/2018 PASS
DetailsMichael Zawacki
Trash on south end is all gone. Some trackout from people driving over sidewalks. Still a few stock piles on site.
General Inspection1/31/20181/31/20181/31/2018 PART
DetailsMichael Zawacki
Most garbage and stockpiles removed from south end of lot. Some trackout onto Gabrielle on south side and apron that is not from bank construction.
Conference11/21/201711/27/201711/29/2017APEND
DetailsAndy J. Long
General Inspection11/29/201711/29/201711/29/2017PFAIL
DetailsMichael Zawacki
check for any stockpiles or trackout issues
Stockpiles still on site. Entire sout perimeter is full of trash. Tracking out on aprons and onto Gabrielle. No protection in drain inlets that receive storm water coming from tracked ouit area.
Conference11/14/201711/14/201711/21/2017PCANC
DetailsAndy J. Long
rescheduled
General Inspection11/13/201711/13/201711/13/2017APEND
DetailsAndy J. Long
Roads, sidewalk and utilities are complete in Shamrock. Homes to be relocated are still on NW corner lot.

New stormdrains do not have sediment protection and some stockpiles and debris remain on lot. Trackout from this staging area due to thrill seekers driving in mud and some dumping.

Construction crew no longer on site. Will work with developer.

No trackout, discharges, or fugitive dust leaving area. Issues are within commercial sub.
Complaint Inspection8/11/20178/11/20178/14/2017AFAIL
DetailsAndy J. Long
Corrections needed:

- have water truck operate in area along the south property line to prevent dust issues for the residential subdivision there.
- sweep road and gutter on Shamrock
- install sediment protection on storm drain on Shamrock
Random Inspection7/24/20177/24/20177/24/2017PPASS
DetailsAndy J. Long
Large capacity water truck being used for fugitive dust control. No plumes observed and no recent complaints received.
General Inspection7/11/20177/12/20177/13/2017PCANC
DetailsMelissa Jannusch
Complaint recieved was about cars being parked on a dirt lot that is across the street from the active construction site. The citizen has been directed to code enforement.
General Inspection7/6/20177/6/20177/7/2017PPEND
DetailsAndy J. Long
Working on northwest corner with no material transport until water truck can be secured.

Onsite foreman stated that their connection hose to the hydrant was stolen and they are working on getting a replacement.
General Inspection6/27/20177/3/20177/3/2017APASS
DetailsAndy J. Long
NO activity at site, no personnel on site. No wind blown dust issues. No corrections.
Complaint Inspection6/29/20176/30/20176/30/2017PPEND
DetailsAndy J. Long
Dust complaint

No activity at time of inspection. No equipment operating. Water trailer is still onsite. NO wind blown dust.

On Thursday developer Jim responded to request by having a full time employee pulling the water trailer.
Complaint Inspection6/23/20176/26/20176/27/2017PCANC
DetailsAndy J. Long
Complaint Inspection6/27/20176/27/20176/27/2017APEND
DetailsAndy J. Long
check for dust control.

Verbal warning issued to RP Rod on Friday PM

Water tank trailer placed onsite. Not in use at time of inspection (11:30 AM), but no fugitive dust leaving site area .

Walk through with RP Rod, request to clean up entrance at east end of site and continue dust control this afternoon.

Will follow up 7/3