Permit Information
Permit NumberESC17-00513
StatusFinaled
Name MATT FORRESTER
Site Address 400 W FORT ST
Project NameBraves Athletic Complex
Customer Number 
ePlanReviewNo
Description
New sports fields and site improvements and stormwater drainage swales to constructed at former BSD operations yard (previously demolished under ESC16-01654). SWPPP with narrative and site map to be kept on site. CGP eNOI tracking # IDR1000FU filed by Beniton Construction. Perimeter sediment controls and inlet protection on surround MS4. Construction entrance to be installed on Collins. Site preaparation inspection required.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final10/25/201810/25/201810/26/2018PPASS
DetailsMichael Zawacki
DOC - Permit Finaled10/26/201810/26/201810/26/2018PPASS
DetailsMichael Zawacki
Site Final10/24/201810/25/201810/25/2018ANR
DetailsMichael Zawacki
Rescheduled for 10/26. Need to see if public works wants witches hats removed from their project on fort st.
General Inspection10/11/201810/11/201810/11/2018 PASS
DetailsMichael Zawacki
Field house is only remaining activity on site. Parking lot is paved and all landscaping complete.
General Inspection9/10/20189/10/20189/10/2018 PASS
DetailsMichael Zawacki
Parking lot complete, crews are now installing sod. Area is expected to have coverage in a week. Field house is nearing completion. No ESC issues at site.
General Inspection8/9/20188/9/20188/9/2018PPASS
DetailsMichael Zawacki
Only observed issue is washout is nearly full. Jan will get it cleaned or new one in before the next sidewalk pour. Water truck on site keeping dust down, no trackout reaching road.
General Inspection7/23/20187/23/20187/23/2018 PASS
DetailsMichael Zawacki
Site is watered and free from dust. Guide line is up for curbing. Construction entrance in place, no tracking to fort. Second approach estimated to begin in the next week.
Tracking Control6/21/20186/22/20186/22/2018PPASS
DetailsAndy J. Long
No muddy trackout to street. Apron needs frequent sweeping or water to keep down dust at entrance. Stockpile is almost hauled off.

Approved.
General Inspection6/21/20186/21/20186/21/2018 FAIL
DetailsAndy J. Long
Trackout to Fort Street. Dump trucks hauling off dirt do have a tracking pad to cross over.

Observed water truck rinsing street without a sweeper, potential for turbid non-stormwater discharge. MS4 inlets have sediment filter bags installed.

Correction request:
- sweep apron, minimize rinsing to be acompanied by sweeping to prevent runoff.

Project manager Jan with Beniton notified of corrections. Stated stockpile hauloff will be completed tomorrow and sweeping and clean will increase instead of installing new rock entrance for this operation.

Follow up tomorrow PM
General Inspection5/21/20185/21/20185/21/2018 PASS
DetailsMichael Zawacki
Met with project manager on site. Site is in good condition. Only correction request was to turn and freshen rock on entrance and to make sure drivers are not going around it.
General Inspection4/20/20184/20/20184/20/2018 PASS
DetailsMichael Zawacki
Phase 2 under way. Pop up classrooms have been removed. Currently grading area and stockpiling, water truck on site. Natural buffer and wattle protecting fort street.
General Inspection3/20/20183/20/20183/20/2018 PASS
DetailsMichael Zawacki
Talked with foreman on site. Phase 1 is complete. Phase two is scheduled to begin in a few weeks, as soon as plans are finalized. BMPs still in place, let them know we will be back when they start to check BMPs.
General Inspection2/15/20182/15/20182/20/2018 PASS
DetailsMichael Zawacki
Area around half complete. Area aroung Cunningham St still exposed.
Site Final12/20/201712/20/201712/22/2017PNR
DetailsAndy J. Long
NR- not ready for site final

WIP. Two soccer/football fields complete and have turf, one softball/baseball field. Frontage along Fort still in progress. No trackout or discharges, no loose trash or materials exposed.

Permit is open. No corrections requested.
General Inspection8/28/20178/28/20178/28/2017APASS
DetailsAndy J. Long
Grading and foundation construction in progress No trackout to Fort Street, water truck and tower on site for dust control, perimeter sediment controls and DI bags installed.
General Inspection8/2/20178/2/20178/2/2017PPASS
DetailsAndy J. Long
No fugitive dust observed. Water truck and onsite filling station in use. No trackout to Fort Street. Site perimeter is clean. Approved.