Permit Information
Permit NumberESC17-00693
StatusFinaled
Name JUSTIN CLARK
Site Address 4665 N TORRIDON WAY
Project NameHH16-4 Apsey
Customer Number 
ePlanReviewNo
Description
Highlands Hackberry 16-4. ESC plan approved. Site preparation inspection is REQUIRED prior to earth disturbance and after installation of BMPs per ESC plan. ESC plan calls for preserving existing vegetation on slopes around the building pad and installing sediment control wattles along the topo contours along the north and west side of SFH footprint. Construction entrance and regular housekeeping/pollution prevention are required.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection7/23/20187/23/20187/23/2018 CANC
DetailsMichael Zawacki
DOC - Permit Finaled7/23/20187/23/20187/23/2018PPASS
DetailsMichael Zawacki
General Inspection7/6/20187/6/20187/6/2018 CANC
DetailsAndy J. Long
General Inspection6/21/20186/21/20186/21/2018 PASS
DetailsAndy J. Long
Random Inspection6/6/20186/6/20186/6/2018PPASS
DetailsMichael Zawacki
Driveway is in and sidewalk has been cut for driveway. Irragation and landscape company on site. No issues.
General Inspection5/24/20185/24/20185/24/2018 PASS
DetailsMichael Zawacki
Site is clean and repaired. Some rilling from gutters, builder will put poly on ground to protect until they get connected to drain.
BMP Violation5/2/20185/9/20185/9/2018APASS
DetailsMichael Zawacki
Check for cleanup of washout and repair of wattle and hill.
Talked to new RP, Justin no longer with company. Sidewalk has been cleaned, stucco has been raked and removed. Old washout has been consolidated in pile. Driveway is scheduled to be poured and curb cut. All will be cleaned when they complete that work.
General Inspection5/2/20185/2/20185/2/2018 FAIL
DetailsMichael Zawacki
Rilling still in front, wattles have failed and sand is on sidewalk.
Concrete, paint, and stucco washed out in back corner of lot and also in front corner.
Second failure for same issues, sending written request to RP and will follow up 5-9. Will put inspection hold on parcel if site not cleaned.
General Inspection4/12/20184/12/20184/13/2018 FAIL
DetailsMichael Zawacki
Lots of rilling in front, wattle is overtopped and runoff is on sidewalk. Wattles need to be maintained and repaired and sidewalks swept. Painters on site, washing out onto ground. Stucco is on site and hasn't begun, mixer has no secondary containment.
General Inspection12/18/20171/4/20181/3/2018ACANC
DetailsAndy J. Long
Random Inspection1/3/20181/3/20181/3/2018PPASS
DetailsMichael Zawacki
BMPs still in place. Framers on site, using trash box. No dirt leaving site.
Random Inspection12/18/201712/18/201712/18/2017PPASS
DetailsAndy J. Long
Permit sign posted. No significant trackout. Perimeter sediment control wattles installed.
Site Preparation11/15/201711/16/201711/16/2017APASS
DetailsMichael Zawacki
John Phone #: ###-####
2 rows of wattle for perimeter protection. Excavation for foundation has already begun.