Permit Information
Permit NumberESC17-01444
StatusFinaled
Name CLINT WALL
Site Address 6829 E WARM SPRINGS AVE
Project NameTribeca B
Customer Number 
ePlanReviewNo
Description
Single Family Dwelling
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Aging Inspection11/2/201811/2/201811/2/2018 CANC
DetailsMichael Zawacki
DOC - Permit Finaled11/2/201811/2/201811/2/2018PPASS
DetailsMichael Zawacki
Conference6/19/20186/20/20186/20/2018ADONE
DetailsAndy J. Long
Meeting with Mike with ProVision Landscaping (208.514.7457) to provide training and BMP flipguide on wattle installation. 9 AM

required installation specifications:
- 8 " wattle
- set wattle in 2-3" deep half circle trench along countour/perimeter (within 1 ft of fence line)
- stake wattles at ends and at 4-5 intervals in between. Adjoining sections should be overlapped 6" and staked tightly together
- backfill trench dirt on upslope side of wattle

Provided BMP booklet and RP manual. Mike will enroll in class as well
General Inspection6/14/20186/15/20186/18/2018APART
DetailsAndy J. Long
follow up to check on perimeter wattle installation

Wattle is now installed along back fence as requested.

Wattle installed not per specifications. No trench. No overlap or tight butting.

General Inspection6/8/20186/12/20186/12/2018PFAIL
DetailsAndy J. Long
follow up

No wattles installed as requested. No change in grading or notification of change in landscaping.

Second correction request to Clint. Need to install before the end of the week.
General Inspection6/8/20186/8/20186/8/2018PFAIL
DetailsAndy J. Long
Backfill from foundations pushed to rear of lot. No perimeter control for sediment and earthen berm that was installed to prevent water from going down slope has been graded over.

Correction request to Clint to re-grade berm and install wattle at bottom of subdivision fence.