Permit Information
Permit NumberESC17-01545
StatusFinaled
Name ROGER WILSON
Site Address 1219 S BROADWAY AVE
Project NameAlbertsons
Customer Number 
ePlanReviewNo
Description
SWPPP submitted and approved. CGP reference IDR1000TN. ESI is operator, Albertson's is owner. Demolition and building site preparation complete, was covered under ESC17-00347. Vertical construction in progress. BMPs include trackout control, MS4 inlet protection, perimeter controls, and pollution prevention in material and staging areas.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final8/21/20188/28/20188/27/2018APASS
DetailsMichael Zawacki
Check for inlet protection removal at Rossi & Grant, Beacon & Grant.
All Removed.
Site Final8/21/20188/21/20188/21/2018PNR
DetailsMichael Zawacki
Withches hats still in drains at Rossi & Grant, Beacon & Grant.
Talked to RP Roger, will get them pulled.
General Inspection7/17/20187/17/20187/17/2018PPASS
DetailsMichael Zawacki
Store is complete and prepped for grand opening. Landscapers on site finishing islands in parking lot. Landscaping material is being stored on Rossi.
Tracking Control5/14/20185/15/20185/15/2018APASS
DetailsMichael Zawacki
Talked with RP, said there should be noone going to Broadway. Will monitor and clean up any trackout.
General Inspection4/26/20184/26/20184/26/2018PPASS
DetailsAndy J. Long
No fugitive observed. Water truck onsite. No trackout or discharges.
Complaint Inspection4/23/20184/23/20184/23/2018PPASS
DetailsMichael Zawacki
Complaint about dust from demo.
Dust was not an issue while I observed work. Signs of water on rubble pile. Currently being loaded into trucks and hauled off.
General Inspection3/30/20183/30/20184/2/2018PPART
DetailsMichael Zawacki
Site is contained, no dirt or trash leaving are. Lots of loose trash is in work area.
General Inspection2/21/20182/21/20182/21/2018PPASS
DetailsMichael Zawacki
Site is well contained, there is a little trackout going out the entrance into Albertsons parkinglot. Site is free from garbage and perimeter BMPs in place.
General Inspection1/12/20181/12/20181/12/2018PPASS
DetailsMichael Zawacki
Perimeter streets free from runoff and dirt. Workers are parking on street, no trackout. Perimeter controls along fence on inside of project. Site is free from trash.
General Inspection11/29/201712/1/201711/30/2017PPASS
DetailsMichael Zawacki
Delivered permit sign.
Perimeter controls intact, no dirt leaving site. DIs in area are protected and maintained. Washouts on site and in use. Mixers are in secondary containment.
General Inspection11/14/201711/14/201711/14/2017PPEND
DetailsMichael Zawacki
ESI knows that they need their own permit. Said NOI has been filed and SWPPP being brought in for review.