Permit Information
Permit NumberESC18-00312
StatusFinaled
Name COREY BLAINE
Site Address 2103 S PEBBLECREEK LN
Project NameFuentes
Customer Number 
ePlanReviewNo
Description
As per ESC Conditions
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Aging Inspection2/3/20202/3/20202/3/2020 CANC
DetailsMichael Zawacki
DOC - Permit Finaled2/3/20202/3/20202/3/2020PPASS
DetailsMichael Zawacki
Aging Inspection12/2/201912/2/201912/2/2019 CANC
DetailsAndy J. Long
Aging Inspection10/1/201910/1/201910/2/2019 PASS
DetailsMichael Zawacki
Site is clean and landscaped.
Aging Inspection7/30/20197/30/20198/1/2019 PASS
DetailsMichael Zawacki
Canal company has issued notice to install wall along creek, rejected bt Army Core.
Site is all contained. Work on patio in rear. Met with landscapers and they will plant to stabalize rear bank.
Tracking Control4/1/20194/4/20194/10/2019PFAIL
DetailsMichael Zawacki
Inlet has not been protected. Driveway still has two mud holes and hasn't been stabalized. Some trackout on street and mud in gutter.
Workers are parked on road today.
Tracking Control3/28/20193/29/20194/1/2019AFAIL
DetailsAndy J. Long
Trackout that was cleaned up has been replaced by more trackout and loose dirt in gutter.

2nd warning. Notified builder Doug ###-#### to stabilzed entrance, fill in area that is a mud puddle. Sweep gutter, install sediment control on receiving storm drain or gutter check bag.

GC said gutter will be swept today, entrance/driveway fixed by Thursday. Follow up scheduled.
Tracking Control3/19/20193/22/20193/28/2019APEND
DetailsAndy J. Long
General Inspection3/19/20193/19/20193/19/2019PFAIL
DetailsAndy J. Long
Corrections needed:

- pick up any loose trash around site
- sweep gutter and dirt in street (push broom ok)
- provide concrete washout for driveway work
- stabilize driveway to prevent trackout

Phone call to RP. Follow up scheduled for Friday.
General Inspection10/18/201810/26/201810/26/2018PPASS
DetailsMichael Zawacki
Home is framed, exterior work remains. Creek behind home is protected by wattle. Nothing leaving site.
General Inspection10/18/201810/18/201810/18/2018PPASS
DetailsAndy J. Long
WIP on frame. Permit posted in window. Backyard adjacent to waterway has preserved vegeation buffer and sediment control wattle installed. No trackout.

Follow up scheduled to make sure pile of wood is hauled away in timely matter. No corrections at this time.
Random Inspection8/7/20188/7/20188/7/2018AFAIL
DetailsAndy J. Long
No ESC permit sign posted.

Need to install sediment control BMP along the creek/canal channel. Less than 50 ft vegetative buffer.

RP is going to schedule onsite conference. He is a new interim RP and taking the class later this month.