Permit Information
Permit NumberESC18-00313
StatusFinaled
Name KALEN SAVARIA
Site Address 1100 S FIVE MILE RD
Project NameFIVE-MILE STORAGE PHASE I
Customer Number 
ePlanReviewNo
Description
To construct a new self storage facility that consists of 10 storage buildings and 1 office/storage building, for a total of 11 new structures on the site.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final10/29/201811/1/201811/5/2018APASS
DetailsMichael Zawacki
Area is paved and phase complete. Still bare areas in middle that will be pads on future storage.
Site Final10/29/201810/29/201810/29/2018PNR
DetailsAndy J. Long
Need to remove sediment bag installed on storm drain @ Common and Smoke Ranch.
General Inspection10/10/201810/10/201810/10/2018PPASS
DetailsMichael Zawacki
No mud issues from rain event. Sunroc on site paving, expected to be done in two days.
General Inspection10/2/201810/2/201810/2/2018PPASS
DetailsMichael Zawacki
Talked to RP, they want to pave 10/3, will not be hauling in any more material. Been having trouble getting sweeper on site.
General Inspection9/19/20189/19/20189/19/2018PPART
DetailsMichael Zawacki
Lots of dirt on Common Ave, none making it to 5 mile. Rear entrance on south side is currently closed.
Sweeper was a no show, earliest time to come is Friday morning.
Tracking Control9/7/20189/10/20189/10/2018APASS
DetailsMichael Zawacki
Currently hauling out stockpile. Sweeper is running on road, water truck on site. Estimate another hour of work to have stockpile removed.
Tracking Control9/6/20189/7/20189/7/2018APEND
DetailsAndy J. Long
Tracking Control9/5/20189/6/20189/6/2018APEND
DetailsAndy J. Long
RP stated clean up has begun, construciton entrances and storm drain protection will be installed by Friday. Rescheduled.
General Inspection9/5/20189/5/20189/5/2018PFAIL
DetailsAndy J. Long
Site is not in compliance:

- trackout at south exit, no rock construction entrance
- need to install a lining on the next concrete washout pit created.

Verbal correction request via vm to RP:
- clean up trackout
- install rock entrances
- follow concrete washout pit construction details.
- install storm drain sediment protection on Smoke Ranch @ Common.
General Inspection8/3/20188/6/20188/6/2018PPASS
DetailsMichael Zawacki
Site is contained. Some large stockpiles on site. Hydrant available for water for dust control.
General Inspection7/27/20187/31/20188/3/2018APEND
DetailsAndy J. Long
General Inspection7/27/20187/27/20187/27/2018PPASS
DetailsAndy J. Long
Conference7/23/20187/23/20187/23/2018PDONE
DetailsAndy J. Long
Project manager notified that the interior of the site will be completed at this time with the rest of the active construction. Cleared by BLD inspector and PW Drainage. No change in permitted area of disturbance.
General Inspection6/19/20186/19/20186/19/2018PPART
DetailsMichael Zawacki
Met with Wright Bros on site. Entrance needs to be freshened up, becoming compacted and a little trackout.
No washout on site yet, trucks have just washed out onto dirt. Permanent washout is scheduled to be built, street is being cleaned and swept as needed.
Verbal correction request issued.
Site Preparation5/24/20185/25/20185/25/2018PPASS
DetailsMichael Zawacki
1 PM

KJ 208.861.8587
Spoke with Jennifer while on site, KJ was at office. Perimeter protected with wattle where needed, most of site is graded below level of adjacent lots. Construction entrance with fabric in place. Water truck on site, metered hydrant very close to site.