Permit Information
Permit NumberESC18-00476
StatusFinaled
Name JIM CARRIVEAU
Site Address 9492 W EMERALD ST
Project NameSalvation Army Grading
Customer Number 
ePlanReviewNo
Description
Permit for grading and utility work for Salvation Army community campus. Building permit is currently being reviewed under permit number BLD17-04447.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final10/17/201910/24/201910/25/2019PPASS
DetailsMichael Zawacki
General Inspection10/11/201910/17/201910/17/2019PCANC
DetailsAndy J. Long
General Inspection10/10/201910/10/201910/11/2019 CANC
DetailsAndy J. Long
Site Preparation9/25/20199/25/20199/25/2019ADONE
DetailsMichael Zawacki
Foreman had esc questions regarding occupancy. Will continue to monitor growth and stabalization.
Site Final9/24/20199/25/20199/25/2019ACANC
DetailsAndy J. Long
General Inspection9/18/20199/18/20199/19/2019 PASS
DetailsMichael Zawacki
Almost all exterior work completed. Area has been seeded. estern edge still has job trailers and an area that hasn't been improved.
General Inspection9/3/20199/3/20199/3/2019 PASS
DetailsAndy J. Long
Final landscaping in progress
General Inspection8/19/20198/19/20198/20/2019 PASS
DetailsMichael Zawacki
Parking lot paved, one section of sidewalk remains. Area is still bare, area around retention pond looks like it still needs to be graded. Silt fence and vegetative buffer still around perimeter. Granite has water truck on site.
General Inspection8/2/20198/2/20198/2/2019 PASS
DetailsMichael Zawacki
Landscapers working at site. Some concrete work remains, washout still on site.Parking lot still needs to be paved.
General Inspection7/17/20197/17/20197/18/2019 PASS
DetailsMichael Zawacki
Topsoil for front has been delivered. Parking lot not paved yet. No trackout or dust.
General Inspection7/2/20197/2/20197/3/2019 CANC
DetailsAndy J. Long
General Inspection6/14/20196/14/20196/14/2019 PASS
DetailsMichael Zawacki
Walked site with foreman. Work on sidewalks and curbing, washout on site is getting full. Majority of work is interior. No ESC issues, gave them new ESC signs.
General Inspection5/30/20195/30/20195/30/2019 PASS
DetailsMichael Zawacki
Talked with Jim the foreman while on site. Crews just starting to prep for sidewalks, new washout will be built, old one was removed yesterday. No ESC isssues at site.
General Inspection5/14/20195/14/20195/16/2019 PASS
DetailsMichael Zawacki
Site contained, no trackout or loosed trash.
General Inspection4/29/20194/29/20195/1/2019 PASS
DetailsMichael Zawacki
Site contained, no ESC issues. Exterior nearly completed.
General Inspection4/12/20194/12/20194/15/2019 PART
DetailsMichael Zawacki
ACHD doing work on Emerald.
No dirt or mud leaving site.
Site does have some loose trash that should be picked up.
General Inspection3/28/20193/28/20193/28/2019 PASS
DetailsMichael Zawacki
No dirt or water leaving site. Workers pumping water to rear of site where it goes into onto site retention, ok since no outlets and uses seepage. No loose trash around site.
General Inspection3/13/20193/13/20193/13/2019 PASS
DetailsMichael Zawacki
No trackout, two rock entrances. Washout on site for mortar. No wind blown trash.
General Inspection2/15/20192/26/20192/26/2019PPASS
DetailsMichael Zawacki
Site is contained, no trackout.
General Inspection2/15/20192/15/20192/15/2019 CANC
DetailsAndy J. Long
General Inspection1/30/20191/30/20191/31/2019 PASS
DetailsMichael Zawacki
Rp has set up barriers to prevent people parking in mud, has been working, no trackout. New washout installed, mortar mixer has secondary containment.
General Inspection1/9/20191/9/20191/9/2019PPASS
DetailsMichael Zawacki
Site is contained and clean. Two stabalized entrances, areas are blocked off to force people to park in correct areas.
General Inspection12/26/201812/26/201812/26/2018 PASS
DetailsMichael Zawacki
Site is contained, silt fence has been repaired, no trackout.
General Inspection12/10/201812/10/201812/10/2018PPEND
DetailsMichael Zawacki
Met with foreman while on site. Will monitor east entrance for trackout, will close and force everyone to west entrance if trackout becomes problem. Has someone scheduled to come and repair silt fence.
General Inspection9/28/20189/28/20189/28/2018PPASS
DetailsMichael Zawacki
Perimeter silt fence in good shape. Two rock entrances installed. No dust at time of inspection.
General Inspection8/24/20188/24/20188/24/2018PPASS
DetailsAndy J. Long
WIP on site work and foundation. Construction entrances installed but are wrong type of rock. No trackout at this time, will need change for Fall DI bags installed on Emerald. No fugitve dust observed. Site is has full silt fence perimeter.
General Inspection8/6/20188/6/20188/6/2018PPASS
DetailsMichael Zawacki
Silt fence surrounding site, construction entrances in place. No loose dust, concrete washout in rear.
General Inspection6/7/20186/18/20186/18/2018PPASS
DetailsMichael Zawacki
Site has perimeter control of silt fence, foreman has someone doing repairs to where wind has damaged it. Rock entrance in place, on;ly way in and out, everyone is forced to go over it.
Will monitor for dust as site dries out.
General Inspection6/7/20186/7/20186/7/2018PPASS
DetailsAndy J. Long
No activity or crew onsite at time of inspection. No trackout, discharges, or fugitive dust observed.
Site grading and utility installation has been completed.

BMPs:
- silt fence perimeter sediment control installation
- rock construction entrance and road mix installed on site haul routes.
- storm drain sediment filter bag installed on MS4 on Emerald.
- City of Boise ESC permit sign posted.

Notified RP that a site preparation inspection should have been conducted and the CGP 2017 permit signage requirements are not posted.