Permit Information
Permit NumberESC18-00845
StatusFinaled
Name BRYAN MURDOCH
Site Address 1897 S WINDSTAR PL
Project Name 
Customer Number 
ePlanReviewNo
Description
As per ESC Conditions. Perimeter sediment control barrier installed below excavation needs to be installed along the contour line or in sections, not along lot boundary as on ESC site map. Preserve existing hillside vegetation as much as possible. Construction entrance required. Site preparation inspection is required.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection10/23/201910/23/201910/23/2019 CANC
DetailsMichael Zawacki
DOC - Permit Finaled10/23/201910/23/201910/23/2019PPASS
DetailsMichael Zawacki
General Inspection10/8/201910/8/201910/9/2019 PEND
DetailsAndy J. Long
Bond for revegetation has expired and the front yard of home is a steep slope with no landscaping or stabilization measures. Will follow up with hillside bond. No offsite runoff issues observed, no temporary BMPs left onsite.
Site Final9/19/20199/20/20199/20/2019ACANC
DetailsAndy J. Long
General Inspection9/19/20199/19/20199/19/2019 CANC
DetailsAndy J. Long
General Inspection9/4/20199/4/20199/4/2019 CANC
DetailsAndy J. Long
General Inspection8/20/20198/20/20198/20/2019 CANC
DetailsAndy J. Long
General Inspection8/2/20198/2/20198/2/2019 PASS
DetailsMichael Zawacki
Waiting on regrowth.
General Inspection7/18/20197/18/20197/19/2019 PASS
DetailsMichael Zawacki
Revegetation in progress.
General Inspection7/3/20197/3/20197/3/2019 PASS
DetailsMichael Zawacki
Hydroseeded and landscaped, waiting on growth.
General Inspection6/18/20196/18/20196/19/2019 PASS
DetailsMichael Zawacki
Site has been hydroseeded, will watch for regrowth. Curbing on driveway to keep water flowing to drain scheduled for installation.
General Inspection5/29/20195/29/20195/29/2019PPASS
DetailsMichael Zawacki
Sprinklers done, hasn't been hydroseeded.
General Inspection5/16/20195/16/20195/16/2019 PASS
DetailsMichael Zawacki
Sprinklers completed, landscapers and hydroseeding supposed to be today.
General Inspection5/1/20195/1/20195/2/2019 PASS
DetailsMichael Zawacki
Home and driveway completed. Site still needs landscaping.
General Inspection4/2/20194/2/20194/2/2019PPASS
DetailsMichael Zawacki
Crew on site installing heaters for future driveway. All water from home runs onto site retention.
General Inspection2/4/20192/4/20192/4/2019PPASS
DetailsMichael Zawacki
No track out into cul-de-sac, workers parked on pavement. Trash box out front with permit displayed. Some small trash is around home.
General Inspection1/2/20191/2/20191/2/2019PFAIL
DetailsMichael Zawacki
Road and sidewalk covered in trackout. Site needs a stabalized entrance.
Message sent to RP.
General Inspection10/9/201810/9/201810/9/2018APASS
DetailsAndy J. Long
rainfall inspection/correction follow up.

RP on duty maintaining storm drain sediment check . Dirt from sidewalk and tracked in culdesac was cleaned before rain, sheet flow is not turbid. Approved.
General Inspection10/4/201810/4/201810/4/2018PFAIL
DetailsMichael Zawacki
Dirt tracked into road. Inlet has sandbag protecting one side, no witches hat. Lots of dirt and sediment running into drain, some has started to pile up along curb. Crane truck on site leaking onto street. Building materials stored on road.
General Inspection10/2/201810/2/201810/2/2018PFAIL
DetailsAndy J. Long
Corrections needed:

- no construction entrance, trackout across sidewalk and in gutter of culdesac. Need to sweep up sidewalk and gutter.
- forklift leaked oil in various spots of culdesac. Absorbent should be applied on any wet spots.
- trash has either been blown or thrown down into vegetation below homesite. Needs to be picked up.
General Inspection8/14/20188/14/20188/14/2018PFAIL
DetailsMichael Zawacki
Washout dumped and ran everywhere. Sent message to RP with pictures.
Site Preparation7/18/20187/18/20187/18/2018PPASS
DetailsMichael Zawacki
Work began without site prep inspection.
Permit displayed, natural buffer in place below home site. Western neighbors yard is protected by silt fence. No stabalized entrance, some dirt on sidewalk. Long exposed driveway, may cause issue if thunderstorm hits site.