Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberESC18-01021
StatusFinaled
Name MITCH CORNELL
Site Address 3001 N LANCASTER PL
Project NameMagal lot2,block 1
Customer Number 
ePlanReviewNo
Description
New Single Family home. Foothills lot. Use of adjacent lots for staging or access must be approved. Site requires perimeter wattle on downslope side of house, properly trenched, staked, and along contour. Prevent trackout with construction entrance. Contain concrete waste and trash. BMP installation and ESC site prepararation inspection is required prior to excavation.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final7/12/20197/17/20197/17/2019PPASS
DetailsMichael Zawacki
General Inspection7/12/20197/12/20197/12/2019 CANC
DetailsAndy J. Long
rescheduled for site final
General Inspection6/27/20196/27/20196/27/2019 PASS
DetailsMichael Zawacki
Lot has been prepped for landscaping, pallets of sod on site.
General Inspection6/12/20196/12/20196/18/2019 PASS
DetailsMichael Zawacki
Home is done, still needs landscaping.
General Inspection5/28/20195/28/20195/28/2019PPASS
DetailsAndy J. Long
Needs final landscaping and stabilization. Home is occupied.
General Inspection5/23/20195/23/20195/23/2019 PASS
DetailsAndy J. Long
Homeowner in process of landscaping, BLD permit has been finaled and a hillside revegetation bond issued. ESC permit to remain open till final stabilization. No corrections requested, no violations.
General Inspection4/30/20194/30/20195/2/2019PPASS
DetailsAndy J. Long
BMP Violation4/8/20194/10/20194/17/2019APART
DetailsAndy J. Long
follow up on corrections

- trash around site picked up
- silt fence repaired
- sidwalk cleaned and front row of gatorguard has been maintained.

Corretions needed:
- scoop up left over stucco waste on adjacent lot
- fix erosion on north side of home due to rooftop runoff without gutters.
- clean up sediment/mud on other side of silt fence.
BMP Violation4/8/20194/8/20194/8/2019PFAIL
DetailsAndy J. Long
Stucco washout dumped all over adjacent lot. Trash laying around adjacent lots and captured in silt fence. Erosion on uphill side of home has knocked down the subdivsion sil fence. No perimeter controls installed on downhill side of lot.

Corrections:
- pick up all trash
- clean up dumped washout
- install gatorguard properly and add section along down hill side
- repair/replace silt fence.
- sweep sidewalk and backfill gatorguard wattles installed per installation specifications.

Verbal correction request to RP-GC.
General Inspection3/19/20193/19/20193/19/2019PPART
DetailsMichael Zawacki
No major ESC issues. SOme trash on silt fence and along side of house, some slurry in street from saw cutting curb for driveway.
General Inspection3/1/20193/1/20193/1/2019PFAIL
DetailsMichael Zawacki
Flatbed truck backed over sidewalk with wheels in dirt, some trackout onto lancaster.
General Inspection1/22/20191/22/20191/22/2019PPASS
DetailsMichael Zawacki
Site clean, no dirt running onto sidewalk or road. Very little building waste.
General Inspection1/10/20191/10/20191/10/2019PPART
DetailsMichael Zawacki
Requested BMPs never installed. Site is clean, trash free. No dirt is leaving site, no trackout to road or sidewalk.
BMP Violation11/29/201812/3/201812/10/2018PNR
DetailsMichael Zawacki
Site is snow covered, unable to see if corrections were made. Did not see wattle along low side.
General Inspection11/29/201811/29/201811/29/2018PFAIL
DetailsAndy J. Long
No trackout and front of site is clean.

Correction request to RP Mitch:
- install perimeter wattle on low corner of site by porta-pot and permit sign.
- pick up trash in gully behind home
- assess rill behind home to prevent further erosion on bank and slope around the deck footings.

RP-GC agreed, said correcitons will be completed this afternoon or tomorrow.

- follow up scheduled Monday Dec. 3 PM
General Inspection10/26/201810/26/201810/26/2018PPASS
DetailsAndy J. Long
WIP. RP - GC on site. No trackout, no spills or discharges. Trash contained. No violations observed. RP stated sidewalk and gutter will be swept this evening.
General Inspection9/24/20189/24/20189/24/2018AFAIL
DetailsMichael Zawacki
No concrete washout, washout has been dumped onto ground.
BMP Violation8/27/20188/27/20188/27/2018PFAIL
DetailsMichael Zawacki
Exacavator tore up wattle in front and didn't clean trackout or sidewalk. Recent rains caused runoff down gutter into DI. Lots of dirt on Lancaster and sidewalk.
Left message with RP Mitch.
Site Preparation8/9/20188/10/20188/10/2018APASS
DetailsMichael Zawacki
Mitch Phone #: ###-####-call to meet.
Will retain grasses as much as possible in rear of site. Most backfill will remain on site. Water wagon will be used for dust. OK to start.