Permit Information
Permit NumberESC18-01273
StatusFinaled
Name ANDREW HOCH
Site Address 12555 W FRANKLIN RD
Project NameFranklin Commerce Ctr - Bldg 1
Customer Number 
ePlanReviewNo
Description
New industrial warehouse with site work consisting of 35464 SF of bldg. shell and core only on 3.12 acres of land.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection4/21/20204/21/20204/23/2020 CANC
DetailsAndy J. Long
Site Final4/23/20204/23/20204/23/2020PPASS
DetailsAndy J. Long
Project complete. Some contained within site need more vegetation, but no runoff issues are occuring. Second phase of project now in progress to the east, see ESC19-01767
General Inspection3/19/20203/19/20203/19/2020 CANC
DetailsAndy J. Long
General Inspection2/17/20202/17/20202/18/2020 CANC
DetailsAndy J. Long
General Inspection1/16/20201/16/20201/16/2020 DEFR
DetailsMichael Zawacki
Need to check stabilazation, wait for area to thaw.
Site Final12/13/201912/16/201912/17/2019PNR
DetailsAndy J. Long
Stockpiles on adjacent lot and back slope revegetation does not seem to be establishing well
General Inspection12/13/201912/13/201912/13/2019 CANC
DetailsAndy J. Long
General Inspection11/12/201911/12/201911/12/2019PPASS
DetailsMichael Zawacki
Building exterior completed and parking lot paved.
Site Final10/22/201910/22/201910/22/2019PNR
DetailsAndy J. Long
Large stockpile from site is still on adjacnet lot. No material leaving site. Will leave open to figure out management of stockpile.
General Inspection10/22/201910/22/201910/22/2019 CANC
DetailsAndy J. Long
reschedule for site final
General Inspection9/20/20199/20/20199/20/2019 CANC
DetailsAndy J. Long
General Inspection8/19/20198/19/20198/19/2019PPASS
DetailsMichael Zawacki
Parking lot paved, still needs landscaping. Job trailer still on east of site.
General Inspection7/18/20197/18/20197/18/2019 PASS
DetailsMichael Zawacki
All current work is in interior of building. Entire lot is pit run, ecopan still at site.
General Inspection6/17/20196/17/20196/17/2019PPASS
DetailsAndy J. Long
General Inspection5/28/20195/28/20195/28/2019PPASS
DetailsMichael Zawacki
Site is surrounded by pit run. Few workers on site, most in interior. No trackout, both exits are stabalized.
General Inspection5/2/20195/2/20195/2/2019PPASS
DetailsMichael Zawacki
Washout on site. Rear hill has been tracked. Tilt up building has walls up, trusses on site. No issues.
General Inspection3/29/20193/29/20193/29/2019PPASS
DetailsMichael Zawacki
No trackout to Franklin.
General Inspection3/7/20193/7/20193/7/2019PPASS
DetailsMichael Zawacki
Running 8 trucks hauling out backfill and bringing in pit run. Road is free from trackout. No one working in mud. Entrances have been built bigger and are being maintained. Ecopans on site.
Site Preparation2/11/20192/12/20192/12/2019APASS
DetailsMichael Zawacki
Met with foreman Gene Hackman. Site has wattle and washout, entrance needs to be improved, said he will get some more rock. Entrance being used jointly between sites. Working on rear hillside to prep for wall, tracked equipment being used to track hillside, will be seeded in spring.