Permit Information
Permit NumberESC18-01284
StatusFinaled
Name CLAYNE BAKER
Site Address 5569 N COLLISTER DR
Project Name5569 N Collister-Noel Res
Customer Number 
ePlanReviewNo
Description
As per ESC Conditions
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final2/12/20202/13/20202/13/2020PCANC
DetailsMichael Zawacki
DOC - Permit Finaled2/13/20202/13/20202/13/2020PPASS
DetailsMichael Zawacki
General Inspection2/12/20202/12/20202/12/2020 CANC
DetailsAndy J. Long
General Inspection1/27/20201/27/20201/27/2020 PASS
DetailsMichael Zawacki
Home is completed. Hillside has blankets installed, no issues. Lot has been sodded. All construction materials have been removed.
General Inspection1/10/20201/10/20201/10/2020 CANC
DetailsMichael Zawacki
General Inspection12/26/201912/26/201912/26/2019 CANC
DetailsAndy J. Long
General Inspection12/11/201912/11/201912/11/2019 PASS
DetailsMichael Zawacki
About half of home is wrapped and has scaffolding. No ESC issues, stabalization in progress.
General Inspection11/26/201911/26/201911/26/2019 CANC
DetailsAndy J. Long
General Inspection11/8/201911/8/201911/8/2019 PASS
DetailsMichael Zawacki
Sod installed on flats. Retaing wall and stairs completed on uphill side. TRM and blankets installed on hillside.
General Inspection10/24/201910/24/201910/24/2019 PASS
DetailsAndy J. Long
General Inspection10/9/201910/9/201910/9/2019 PASS
DetailsMichael Zawacki
Mini excavator working on retaining wall on uphill side of home. Still some material stored on site.
General Inspection9/23/20199/23/20199/23/2019PPASS
DetailsMichael Zawacki
Mini excavator working along uphill side of driveway, looks like prep for a wall. Backfill being loaded into trailer. Some compacted dirt on rpoad.
General Inspection9/11/20199/11/20199/11/2019 PASS
DetailsMichael Zawacki
Looks like road has been scraped clean. Materials still stored on road.
General Inspection8/27/20198/27/20198/27/2019PPART
DetailsMichael Zawacki
Hillside above home has no protection. Road is dirty around the area they are using for storage.
General Inspection8/22/20198/22/20198/22/2019 CANC
DetailsAndy J. Long
General Inspection8/7/20198/7/20198/7/2019 PART
DetailsMichael Zawacki
Materials still stored in road. Drywall work has begun, scraps piled in front of home. Road is dirty.
General Inspection7/23/20197/23/20197/23/2019 PASS
DetailsMichael Zawacki
No workers on site.
Uphill side my cause issues if not stabalized before rain starts.
General Inspection7/8/20197/8/20197/8/2019PPASS
DetailsMichael Zawacki
Pit run drive drive and walkway installed. Some material stored on road. No runoff from site.
General Inspection5/29/20195/29/20195/29/2019PPASS
DetailsMichael Zawacki
Some building material stored in road. Front lot is pitrun. No ESC issues, no runoff going down hill.
General Inspection3/27/20193/27/20193/27/2019PFAIL
DetailsMichael Zawacki
Lots of dirt on road in front of house. Previously talked to builde about keeping site clean.
General Inspection3/7/20193/7/20193/7/2019PPEND
DetailsMichael Zawacki
Framers on site. Some dirt on road from backfilling. Framers said they will let RP know to get it cleaned up.
General Inspection2/1/20192/1/20192/1/2019PPART
DetailsMichael Zawacki
Most styrofoam cleaned, still one area where fence is under load. Fresh concrete pour, no dumped washout.
General Inspection1/17/20191/29/20191/29/2019PPART
DetailsMichael Zawacki
Foundation poured, no dumped washout. Silt fence under heavy loads in areas. Lots of loose styrofoam around site, needs to be cleaned. Runoff risk from top of site.
General Inspection1/17/20191/17/20191/17/2019PPASS
DetailsAndy J. Long
WIP. Silt fence perimerter control is working. No discharges or muddy trackout extending out of culdesac.

- Need to work on the frozen mud that is now thawing directly in front of site to get a cleaner surface.

Homeowner is GC, builder onsite Chet Clark said he would clean up. Will need to watch stockpile of backfill if there is any left over after.

Notified Chet of washout requirements.
General Inspection11/27/201811/27/201811/27/2018PFAIL
DetailsMichael Zawacki
Wattle and silt fence has been installed, neither are trenched in and will do nothing to prevent run off.
Multiple outpak washouts at site.
Site Preparation11/7/201811/8/201811/8/2018APASS
DetailsAndy J. Long
930 am

Pre construciton review of ESC plan with RP-excavator Buzz and homeowner Fabian.

On downhill side of lot perimeter silt fence with J hook outlet will be install. WIll set back from street a bit to utilize the existing flat grassy area.

Review concrete washout containment options. Brooms for daily sweeping are on site. Homeowner has talked to neighbors. No sediment protection requested on downstream inlet due to disctance and large drainage area for system. Will keep dirt on site and monitor trackout.

Permit posted. Approved for construction.
Site Preparation11/7/201811/7/201811/8/2018PCANC
DetailsAndy J. Long
Fabin-please Fabin call to meet Phone #: ###-####

rescheduled