Permit Information
Permit NumberESC18-01447
StatusIssued
Name BERLUM DEVELOPMENT CO
Site Address 1673 W SILVER CREST DR
Project Name 
Customer Number 
ePlanReviewNo
Description
As per ESC Conditions. ESC plan with narrative and site map approved. Site preparation inspection is required before earthwork and after BMP installation. BMPs include perimeter sediment control wattles, stabilized construction entrance, and permit signage.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection8/6/20208/6/20208/6/2020 PASS
DetailsMichael Zawacki
Home is framed, starting to be prepped for stucco. Some material still being stored in lot. Large dumpster on site, no issues.
General Inspection7/22/20207/22/20207/24/2020 CANC
DetailsAndy J. Long
General Inspection7/7/20207/7/20207/9/2020 CANC
DetailsAndy J. Long
BMP Violation6/19/20206/22/20206/24/2020PPART
DetailsMichael Zawacki
Road and DI bag cleaned. Still only has one gator guard installed. Piece of concrete placed in front of pipe to act as difuser. Rilling from roof not cleaned.
BMP Violation6/8/20206/11/20206/19/2020PCANC
DetailsAndy J. Long
General Inspection6/2/20206/3/20206/8/2020PFAIL
DetailsAndy J. Long
check for perimter controls and DI bag clean up

DI bag was replace and a new gator guard perimeter control was installed on low corner of lot.

Flow was too great for loosely installed wattle and DI bag is now full of dirt from the site.

Correction request to RP James to replace wattle with silt fence or add additional wattles/check dams to slow the flow of the runoff from the roof and to maintain the sediment bag....
General Inspection6/2/20206/2/20206/2/2020PFAIL
DetailsAndy J. Long
Inadequate perimeter sediment control allowing runoff generated by roof to cause erosion and seidment runoff to storm drain down hill.

Correction request:
- install perimeter sediment control
- clean out storm drain sediment bag

Text and pictures sent to RP James with Berlum
General Inspection5/29/20205/29/20205/29/2020 PASS
DetailsAndy J. Long
General Inspection5/14/20205/14/20205/14/2020PFAIL
DetailsMichael Zawacki
Some trackout from one person who tried parking on mud. Notified to clean up, sit has good response and has been in compliance.
General Inspection4/30/20204/30/20205/1/2020 PASS
DetailsMichael Zawacki
Site is clean. Hillside has a lot of growth and no erosion issues.
General Inspection4/15/20204/15/20204/15/2020 PASS
DetailsMichael Zawacki
Site is clean and contained. No blowing trash.
General Inspection3/31/20203/31/20203/31/2020PPASS
DetailsAndy J. Long
No activity at site. No runoff or trackout issues on street. Need to check back slope next inspection.
General Inspection3/19/20203/19/20203/19/2020 PASS
DetailsMichael Zawacki
Site is clean and contained.
General Inspection3/4/20203/4/20203/4/2020PPASS
DetailsMichael Zawacki
Site is clean and contained. No issues.
General Inspection2/21/20202/21/20202/21/2020PPASS
DetailsMichael Zawacki
Site is clean and contained.
General Inspection2/12/20202/12/20202/13/2020 PASS
DetailsMichael Zawacki
Work hasn't begun
General Inspection1/27/20201/27/20201/27/2020PPASS
DetailsMichael Zawacki
Met with framers on site. Everything clean, no one driving off or on site with vehicles or equipment.
Will need to use crane on site and plan on making plywood path.
General Inspection1/15/20201/15/20201/15/2020PCANC
DetailsMichael Zawacki
General Inspection1/3/20201/3/20201/3/2020 PASS
DetailsMichael Zawacki
No workers on site.
All material on lot, no loose trash. Hillside is stable.
General Inspection12/19/201912/19/201912/19/2019PPASS
DetailsMichael Zawacki
All workers parked on street. Entire lot is a staging area for lumber. No issues.
General Inspection12/10/201912/10/201912/10/2019 PASS
DetailsMichael Zawacki
WIP on framing. Hillside is doing OK, two drains now daylight midway down the hill. eNTRANCE IS SAND, ROAD IS SWEPT, TRASH CONTAINED.
General Inspection11/21/201911/25/201911/26/2019PPASS
DetailsAndy J. Long
No activity. No trackout or loose trash. Will need to do winter conference
General Inspection11/19/201911/19/201911/21/2019 CANC
DetailsAndy J. Long
General Inspection11/1/201911/1/201911/1/2019PPASS
DetailsMichael Zawacki
Hillside has been hydroseeded and tackified. Washout cleaned and ecopan now on site. Mini excavator doing rock work on perimeter of lot.
General Inspection10/17/201910/17/201910/17/2019PFAIL
DetailsMichael Zawacki
Form trailers now off site.
Washout that was parked over not cleaned.
New entrance needs to be installed.
Hillside has no hydroseeding or stabalization.
Conference10/4/201910/4/201910/4/2019PPASS
DetailsMichael Zawacki
Met with RP on site. Went over corrections and concerns.
Veasy scheduled to hydroseed, new entrance will be installed when backfill removed.
Gave ok to remove hold.
General Inspection10/2/201910/2/201910/2/2019PFAIL
DetailsMichael Zawacki
Concret work in progress. No washout container on site, washout dumped behing backfill.
General Inspection9/26/20199/26/201910/2/2019PCANC
DetailsAndy J. Long
General Inspection9/25/20199/25/20199/25/2019 PASS
DetailsMichael Zawacki
Area excavated for foundation, large pile of backfill on site. Hillside has lots of bare ground, message sent to RP suggesting stabilaztion or slope interuption.
General Inspection9/5/20199/5/20199/5/2019 PASS
DetailsMichael Zawacki
Inspected 9-4.
Backfill has been replaced behind wall, stockpiles cleaned up.
Conference8/21/20198/21/20198/29/2019PDONE
DetailsAndy J. Long
Update permit for new contractor

New contractor did not notify ESC division they would be taking over site.

Berlum Construction RPs have been added to permit. Permit transfer has been assessed, $52.50


Tracking Control8/21/20198/21/20198/21/2019PDEFR
DetailsMichael Zawacki
New contractor, listed RP no longer working for owner, will need to update permit.
General Inspection8/15/20198/15/20198/15/2019PFAIL
DetailsMichael Zawacki
Trackout, message and picture sent to RP.
General Inspection8/7/20198/14/20198/13/2019ACANC
DetailsMichael Zawacki
General Inspection8/7/20198/7/20198/7/2019 FAIL
DetailsMichael Zawacki
Site needs trashbox and someone missed washout. Sent message to RP, follow up scheduled.
General Inspection6/25/20196/25/20196/25/2019PPART
DetailsAndy J. Long
No activitiy at site. No trackout or sediment runoff. Large stockpiles of backfill are becoming a source of fugitive dust during wind.

Correction request to flatten, remove, or stablize stockpiles (tacifier) to mitigate dust issues

VM left with RP Jason
General Inspection4/30/20194/30/20195/2/2019PPASS
DetailsAndy J. Long
Permit sign posted. Construction entrance and lined concrete washout installed and in use. Perimeter vegetation preserved and downhill wattles and silt fence installed in addition to vegetation. No corrections requested.
General Inspection4/18/20194/18/20194/18/2019PPASS
DetailsMichael Zawacki
Excavation has begun. Backfill stored on site. No ESC issues.
General Inspection4/9/20194/9/20194/9/2019PPASS
DetailsMichael Zawacki
Syman on site installing BMPs. Work expected to start 4/9
Site Preparation3/28/20193/29/20193/29/2019ADONE
DetailsAndy J. Long
9 AM w/ Jason

Pre-con only. No BMPs yet. Reviewed site. Potential changes to grading and draiange deferred to PW hillside.

Request for beefy long construciton entrance and leak proof washout solution.