General Inspection | 8/27/2019 | 8/27/2019 | 8/27/2019 | P | CANC |
Michael Zawacki
|
|
|
|
DOC - Permit Finaled | 8/27/2019 | 8/27/2019 | 8/27/2019 | P | PASS |
Michael Zawacki
|
|
|
|
Complaint Inspection | 5/6/2019 | 5/7/2019 | 5/7/2019 | A | FAIL |
Andy J. Long
|
|
|
Concrete/concrete washwater spilled or dumped along Roe Street and a pile in the stormwater swale. Loose dirt and material on Tarako and Limelight. No trackout from subdivision, some trash containers installed and in use. Workers parking on the pavement. Lined washout installed east of townhomes.
Correction requests: - clean up dumped material in swale - shovel scrape and broom the dried cementitious material in the gutter along Roe Street - clean up around storm drain inlet, including curb cut and muck out the mud on the drain apron and entry to sand swale. - install silt fence on inside of sidewalk along Roe and around the corner on Limelight - build two more trash boxes on Tarako - Sweep limelight between Roe and Tarako - notify crews to pick up and contain all trash daily. - designate a staging area for unloading materials and trusses to prevent blocking streets and gutters for cleaning and access.
|
Complaint Inspection | 5/6/2019 | 5/6/2019 | 5/6/2019 | P | CANC |
Andy J. Long
|
|
|
|