Permit Information
Permit NumberESC18-01770
StatusIssued
Name ROBERT GOODWIN
Site Address 982 N MAPLE GROVE RD
Project NameRosewood Apartments Expansion
Customer Number 
ePlanReviewNo
Description
Building #11: Located along Maple Grove and Susan. Perimeter sediment controls around all new expansion areas. Install lined heavy duty rock construction entrance off Susan. Protect MS4 inlets on Maple Grove and Irving. Site preparation inspection is REQUIRED after BMPs installed and prior to earthwork.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection8/3/20208/3/20208/3/2020 PASS
DetailsMichael Zawacki
Landscapers working from sout tho nort. Sunroc on site repairing pavement. Peopl moving into south building, still interior work on northern building.
BMPs still installed on maple grove.
General Inspection6/16/20206/16/20206/16/2020 PASS
DetailsMichael Zawacki
General Inspection5/1/20205/1/20205/5/2020 PASS
DetailsMichael Zawacki
Crews finishing up concrete curb work on site, sidewalks have been completed. Scheduled to pave parking lot on tuesday the 12th.
Susan drive is closed and is getting repaired.
Irragation water is backing up into parking area on north side.
Buildings framed and only interior work remains.
General Inspection3/16/20203/16/20203/16/2020 PASS
DetailsAndy J. Long
BMPs installed - stabilzed staging area, concrete washout pans onstie. Fenced permeter and inlet protection on Maple Grove.

WIP. Not corrections requested at this time.
General Inspection1/28/20201/28/20201/28/2020 PASS
DetailsMichael Zawacki
Rocks now spread into parking area on south building. Will continue to monitor for tracking.
Tracking Control12/4/201912/12/201912/12/2019PFAIL
DetailsMichael Zawacki
Met with Kris at site. They are getting more rocks and will schedule a sweeper. Interested in trying wood chip for parking area. Will build a road in the site for access. Curently trailers in mud and genie lift tracking running from site to storage.
General Inspection11/29/201912/3/201912/4/2019PPASS
DetailsAndy J. Long
No construction entrance of stabilized parking area for employees. No significant trackout to Maple Grove, some on Irving.

Request issued to RP Bob with Wright Brothers to get entrance installed and clean up.

Follow up scheduled.
General Inspection11/28/201911/28/201911/29/2019 CANC
DetailsAndy J. Long
General Inspection10/8/201910/8/201910/8/2019PPASS
DetailsMichael Zawacki
Met with WB foreman at site.
Concrete slabs being put in, trucks using washout and also ordered washout low enough for pump trucks.
Framing has begun on southernmost units. Seepage bed dug. Crew was on site cleaning trash.
Plan to have area paved before winter.
General Inspection8/19/20198/19/20198/19/2019PPASS
DetailsMichael Zawacki
WIP on foundations. Ecopans at site, no dust or trackout, site contained.
Site Preparation7/15/20197/15/20197/15/2019PPASS
DetailsMichael Zawacki
Work began without site prep. Foreman was going off of temp occupancy card and not rough in, ESC is not listed as inspection and was overlooked.
Water truck on site, no dust. Construction entrance made with round rock, contactors will sweep up trackout as needed.
Site is below grade, no perimeter control needed for current phase.
DIs around site have been protected.
Gave them permit signs to put on site.