Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberESC19-00283
StatusFinaled
Name JASON JONES
Site Address 2104 N 13TH ST
Project NamePHASE 2 CAMEL'S BACK CHUTE
Customer Number 
ePlanReviewNo
Description
CAMELS BACK CHUTE STABILIZATION PHASE 2 PROJECT. ESC stand alone permit, plans created by Public Works. No GRD permit. ESC plan approved. Site will need temporary stabilization and sediment control during revegetation. Must use specified seed mix and application rate. Site preparation and site final inspection are required.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final5/18/20205/18/20205/19/2020PPASS
DetailsAndy J. Long
Coverage on disturbed area has met 70% revegetation. Jute matting ECB is firmly atatched, no rips or erosion from area observed. No temporary BMPs left behind.

Parks management will remove fencing when they are ready, they may be returning to apply preemergent herbicide to control invasives.

No ESC requests related to construction. ESC permit connditions satisfied.
General Inspection5/1/20205/1/20205/4/2020 PASS
DetailsMichael Zawacki
Been in communication with RP regarding final stabilization. Has been seeded and has jute matting. Parks dept will make call if they are ok with measures. Will continue to monitor site.
General Inspection4/16/20204/16/20204/16/2020 PASS
DetailsMichael Zawacki
Has blanket and is fenced.
General Inspection4/1/20204/1/20204/1/2020 PASS
DetailsMichael Zawacki
General Inspection3/17/20203/17/20203/17/2020 PASS
DetailsMichael Zawacki
Revegetation in progress. Parks dept made repairs after parents ripped out fences to let their kids sled.
General Inspection2/28/20202/28/20203/2/2020 CANC
DetailsAndy J. Long
General Inspection2/6/20202/6/20202/6/2020 CANC
DetailsAndy J. Long
General Inspection1/22/20201/22/20201/22/2020 CANC
DetailsAndy J. Long
General Inspection1/3/20201/3/20201/3/2020 PASS
DetailsMichael Zawacki
Still fenced off.
General Inspection12/13/201912/13/201912/17/2019 PEND
DetailsAndy J. Long
Erosion control blankets are still well intact, some staples have come loose, but no significant tenting or undercutting observed.

Activity is complete, monitoring revegetation. Lots of weeds seem to have established, but hard to tell until next Spring.

Site should have the construction fencing fixed to keep people off the area revegetating and to preserve the erosion control blankets.

Okay to reduce inspection frequency for winter.
General Inspection9/20/20199/20/20199/20/2019PPASS
DetailsMichael Zawacki
check on revegetation and any issues with blankets
Revegetation is much stronger on west side. East side of stairs sparse. Blankets are still in place, no obvious issues.
General Inspection5/16/20195/22/20195/22/2019APASS
DetailsAndy J. Long
ECBs endured the heavy rainfall. No issues detected. No hydroseeding has occured yet. No requests at this time.
General Inspection5/15/20195/16/20195/16/2019APASS
DetailsAndy J. Long
Stairs have been set. Jute mat ECB is all installed and is anchor trenched, landscaping staples, and shingled properly with upper section overlapping downslope sections. Minimal tenting observed. Jute is ready for seeding.

Work area is clean, no trackout or other issues observed.
General Inspection4/26/20194/29/20194/29/2019APEND
DetailsAndy J. Long
Check that coir mats have been installed correctly...

Mats installed have anchor trench and staples securing it to ground. No tenting observed. Mats rolled down slope in correct direction and overlap sections installed downslope

Need to review construction plans and provide installation specs for mats in the project binder.

Plan is to hydroseed over the mats with a dryland seed mix.
General Inspection4/16/20194/17/20194/19/2019PPASS
DetailsMichael Zawacki
Crews on site. Nothing leaving exposed work area. Park is busy.
General Inspection4/8/20194/9/20194/16/2019PCANC
DetailsAndy J. Long
General Inspection4/1/20194/2/20194/8/2019PCANC
DetailsAndy J. Long
Site Preparation3/19/20193/20/20193/20/2019ADONE
DetailsMichael Zawacki
Work area is blocked by construction fence. Equipment staged in a fenced of area, ecology blocks at bottom. No BMPs installed on hillside, will monitor as construction begins.