Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberESC19-00315
StatusFinaled
Name ROBERT SILVA
Site Address 2207 W SPAULDING ST
Project Name2207 spaulding
Customer Number 
ePlanReviewNo
Description
per ESC conditions
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection9/20/20199/20/20199/20/2019PCANC
DetailsMichael Zawacki
DOC - Permit Finaled9/20/20199/20/20199/20/2019PPASS
DetailsMichael Zawacki
General Inspection8/26/20198/26/20198/26/2019PPASS
DetailsMichael Zawacki
OK to final when witches hat pulled from drain at columbus.
General Inspection7/18/20197/18/20197/18/2019PPASS
DetailsMichael Zawacki
Exterior completed and site landscaped. No ESC issues.
General Inspection4/25/20194/25/20194/25/2019PPART
DetailsMichael Zawacki
Some backfill spilling onto sidewalk. Message and picture sent to RP.
BMP Violation4/17/20194/19/20194/19/2019PPASS
DetailsAndy J. Long
WIP on foundation. RP installed sediment protection and cleaned up gutter on Spaulding.

Concrete pump truck at site at time of inspection. NW pumping services has been directed to washout offsite at Sunroc yard.
BMP Violation4/15/20194/16/20194/17/2019PPEND
DetailsAndy J. Long
RP called to notify he will work on corrections and install sediment protection on drain after cleaining out the inlet sump. Follow up scheduled
BMP Violation4/15/20194/15/20194/15/2019PFAIL
DetailsAndy J. Long
Corrections needed:
- clean out mud from receiving storm drain sump
- clean gutters on Spaulding and Columbus
- install sediment protection on stromdrain
- place porta-pot on level ground and stake down
- install concrete washout asap before foundations.

VM left with RP Bobby with with Wood River