Permit Information
Permit NumberESC19-00444
StatusFinaled
Name MAGNUM KINCAID
Site Address 1840 N MOCKBEE PL
Project NameMockbee House - 1840 N. Mockbe
Customer Number 
ePlanReviewNo
Description
per ESC conditions
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection7/20/20207/20/20207/20/2020 CANC
DetailsMichael Zawacki
DOC - Permit Finaled7/20/20207/20/20207/20/2020PPASS
DetailsMichael Zawacki
General Inspection7/3/20207/3/20207/6/2020 CANC
DetailsAndy J. Long
General Inspection6/18/20206/18/20206/18/2020 PASS
DetailsMichael Zawacki
Landscapers on site.
General Inspection6/3/20206/3/20206/3/2020 PASS
DetailsMichael Zawacki
Terravita is on site installing mason landscape wall. Lot still needs to be landscaped.
General Inspection5/19/20205/19/20205/19/2020 PASS
DetailsAndy J. Long
BLD now finaled and home occupied. Revegetation bond issued, landscaping not yet installed and perimeter silt fence is in place

General Inspection5/4/20205/4/20205/4/2020 PASS
DetailsMichael Zawacki
Home is completed, still needs landscaping. Perimeter silt fence still installed, few trees planted, landscaping has begun.
General Inspection4/16/20204/16/20204/16/2020 PASS
DetailsMichael Zawacki
No workers on site. Exterior construction looks completed. Site is clean, still needs landscaping.
General Inspection4/1/20204/1/20204/1/2020 PASS
DetailsMichael Zawacki
Exterior work looks completed. All trash is going into trailer on site.
Lot still needs landscaping.
General Inspection3/17/20203/17/20203/17/2020 PART
DetailsMichael Zawacki
Some small trash along perimeter.
Silt fence above site is damaged, only serves as a fence, no esc use. Street and sidewalk clean.
General Inspection2/28/20202/28/20202/28/2020 PASS
DetailsMichael Zawacki
Lots of workers at house, have cul de sac blocked. Will need to make sure sidewalk and street is swept.
General Inspection2/11/20202/13/20202/13/2020AFAIL
DetailsMichael Zawacki
Pitrun stored on road. Most has been scraped, still dirty, rucks parked on top of where it was.
General Inspection1/29/20201/29/20201/31/2020 CANC
DetailsAndy J. Long
General Inspection12/20/201912/20/201912/20/2019 PASS
DetailsMichael Zawacki
Pump truck on site, haven't started pouring, no mud yet on site. Work is retaining wall, washout provided.
General Inspection10/25/201910/28/201910/29/2019APASS
DetailsMichael Zawacki
No dumped washout, did not see concrete washout container at site.
Trash is getting full, will need to empty and watch for wind blown.
General Inspection10/25/201910/25/201910/25/2019PPEND
DetailsAndy J. Long
No washout on site for pump truck at site. Request to RP to have a washout built. RP had on site foreman begin to build a washout containment as I was on site. Will follow up Monday.
General Inspection6/4/20196/18/20196/18/2019PPASS
DetailsMichael Zawacki
Basement excavated. Forms and rebar in place, no concrete pour yet, site needs washout. All contained, no dust or trackout.
Site Preparation6/4/20196/4/20196/4/2019PPASS
DetailsAndy J. Long
please call Magnum Phone #: ###-####

Permit sign posted. RP onsite with ESC plan.

Installing silt fence to preserve clearing limits above excavation area rather than as a sediment barrier. RP to leave grass buffer to the right of the site access, additional wattle onsite to install after excavation.

Using large Outpak for washout containment.

Approved for construction.