Permit Information
Permit NumberESC19-00589
StatusFinaled
Name LLOYD L PORTER
Site Address 4101 N CARTWRIGHT RD
Project Name 
Customer Number 
ePlanReviewNo
Description
per attached ESC conditions. Preserve existing vegetation and remain within designated clearing limits, run on diversion ditches may be required to be installed to deal with the steep western slope. Heavy duty construction entrance and down gradient perimeter sediment barrieers are requiered. Site preparation inspection is REQUIRED prior to significant earthwork and after BMPs are installed.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection6/25/20206/25/20206/25/2020 CANC
DetailsMichael Zawacki
DOC - Permit Finaled6/25/20206/25/20206/25/2020PPASS
DetailsMichael Zawacki
General Inspection6/10/20206/10/20206/10/2020 PASS
DetailsMichael Zawacki
Will continue to monitor for revegetation and rilling.
General Inspection5/26/20205/26/20205/26/2020 PASS
DetailsMichael Zawacki
Grass planted along driveway. Some dirt and rilling still on hillside.
General Inspection5/7/20205/7/20205/11/2020 PASS
DetailsMichael Zawacki
Hillside still needs to be vegetated.
General Inspection4/21/20204/21/20204/21/2020 PASS
DetailsMichael Zawacki
Upper area along driveway has been tackified. Hillsides still bare.
General Inspection4/3/20204/3/20204/7/2020 PASS
DetailsAndy J. Long
Reviewed homeowners plan to complete revegetation & stabilization.

- finish all site drainage features per the approved grading and drainage plan
- hydroseed disturbed slope areas along Cartwright road. Remove loose dirt on sage brush and living vegetation; repair slopes with visible erosion damage/rake out rills

- hydroseed triangular area between driveway, parking area and Cartwright. Recommend doing some soil prep and topsoil spread, area is compacted.
- homeowner is fencing in backyard and will finish landscaping over time
- homeowner/builder should review hillside development revegetation and erosion control standards, 11-7-08 subsection 5 C
General Inspection3/18/20203/18/20203/18/2020 FAIL
DetailsMichael Zawacki
Work has started on fence. Lot of area disturbed on hillside above cartwright, new rills forming.
General Inspection3/3/20203/3/20203/4/2020 PASS
DetailsMichael Zawacki
Hillside along cartwright still needs to be stabalized.
General Inspection2/4/20202/4/20202/6/2020 PART
DetailsMichael Zawacki
Steep hillside along cartwright bare and has no BMPs
General Inspection12/12/201912/12/201912/12/2019PPASS
DetailsMichael Zawacki
Driveway poured and home exterior completed. Hillside above Cartwright still not repaired or stabalized. ZNot landscaped along driveway.
General Inspection11/19/201911/19/201911/19/2019PPASS
DetailsAndy J. Long
General Inspection8/27/20198/27/20198/27/2019PPASS
DetailsMichael Zawacki
Site is clean, all wood scraps going into trailer on site. No loose or blowing trash. Hillside where water came up still bare.
Los of dust when driving into site, no dust otherwise.
General Inspection7/8/20197/8/20197/8/2019PPASS
DetailsMichael Zawacki
Foundation has been poured and washout used. No dirt has run down hill to road, area of hill was disturbed to run sewer.
Water has been hooked up and used for dust control. All materials stored up on site.
General Inspection6/6/20196/13/20196/13/2019PPASS
DetailsMichael Zawacki
Hillside is not disturbed, excavation is right to edge and there is no BMPs. Excavation for home has begun, backfill on site. No concrete washout installed.
Site Preparation6/6/20196/6/20196/6/2019PPASS
DetailsAndy J. Long
Reviewed ESC plan with RP. Crew in process of installing rock construction entrance on existing site access. Building pad is flat. Will preserve the vegetated bank and earthen berm along the edge everywhere exempt where house and water line come in from Cartwright.

Will install lined concrete washout. Approved to start. RP-GC Lloyd to be onsite daily.

Follow up scheduled.