Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberESC19-00935
StatusIssued
Name JOHN LAUDE JR
Site Address 4585 E VICTORY RD
Project NameSabana Subdivision
Customer Number 
ePlanReviewNo
Description
per ESC conditions. ESC plan approved. Heavy duty construction entrance, fugitive dust control, concrete washout containment are required. Site preparation inspection is REQUIRED prior to rough grading. Silt fence sediment barrier to be installed to protect irrigation ditch adjacent to site. Will be building onsite stormwater retention ponds.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection7/27/20207/27/20207/27/2020PPASS
DetailsMichael Zawacki
Noo workers on site.
Sidewalks and curb work has begun. Two washouts on site, nonen dumped on ground.
Road be in place, no paving. Lots of bare area.
General Inspection6/5/20206/8/20206/9/2020PPASS
DetailsMichael Zawacki
No new activity at site, starting to overgrow
Aging Inspection6/5/20206/5/20206/5/2020 CANC
DetailsAndy J. Long
General Inspection3/3/20203/17/20203/23/2020PFAIL
DetailsAndy J. Long
No activity at site. No trackout or discharges from site. No wind blown dust observed at time of inspection.

Site is out of compliance for stabilzation deadlines. Incactive disturbed area and stockpiles with no temporary statbilization.
General Inspection3/3/20203/3/20203/3/2020PPART
DetailsAndy J. Long
No activity, no trackout. Dry conditions. No wind blown dust observed at time of construciton.

Corrections needed:
- updated construction schedule
- stabilize stockpile or become active. Beyond stockpile stabilization deadline
- install new construction entrance prior to resuming grading activity

Notified RP John. He will provide updates and schedule on corrections.

Follow up inspection scheduled
General Inspection2/24/20202/24/20202/24/2020PPASS
DetailsMichael Zawacki
Site utility prep work is completed. No workers on site. Area is all bare, large stockpile at site.
Tracking Control12/6/201912/9/201912/10/2019PPASS
DetailsMichael Zawacki
Talked to foreman while at site. Had entrance rerocked yesterday. Not expecting any deliveries or anyone coming to site. Area is clean, no dirt leaving perimeter.
General Inspection12/6/201912/6/201912/6/2019PFAIL
DetailsAndy J. Long
No construction entrance or stabilized area for workers. Some trackout onto Victory.

Notified RP to have SCE installed, follow up scheduled.
General Inspection10/30/201910/30/201910/30/2019PPASS
DetailsMichael Zawacki
Site is rough graded. East side below grade of neighboring lot, west iha silt fence, small section damaged, looks like game trail going over it, no dirt breached.
WIP on sewer, victory is closed, work in street and parcel. Water truck on site, fuel and maintenace vehicle also on site, one person doing fueling.
General Inspection10/8/201910/8/201910/9/2019PCANC
DetailsMichael Zawacki
Site Preparation8/29/20198/29/20198/29/2019APASS
DetailsAndy J. Long
w/ John RP

Silt fence perimeter on down gradient site border and irrigation ditch has been properly installed. SWPPP permit posted. Construction to begin next week or following week, will post City of boise ESC permit sign and install heavy duty construction entrance.