Permit Information
Permit NumberESC19-01053
StatusFinaled
Name SCOTT COLLINS
Site Address 1475 N COLE RD
Project NamePRIMARY HEALTH COLE & FAIRVIEW
Customer Number 
ePlanReviewNo
Description
DEMOLISH EXISTING BUILDING AND RELATED SITE IMPROVEMENTS, AND CONSTRUCT A 6,340 SF PRIMARY HEALTH MEDICAL CLINIC WITH SITE IMPROVEMENTS AND LANDSCAPING
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection8/3/20208/4/20208/4/2020PCANC
DetailsMichael Zawacki
DOC - Permit Finaled8/4/20208/4/20208/4/2020PPASS
DetailsMichael Zawacki
General Inspection7/14/20207/14/20207/14/2020 PASS
DetailsMichael Zawacki
Primary health is finished. Resr of site still bare. Will leave permit open to monitor site.
General Inspection5/27/20205/27/20205/27/2020PPASS
DetailsMichael Zawacki
Clinic is about completed, landscapers finishing up.
Met with foreman while on site and they will be doing the next projects. Owners undecided if they will pave remaining lots or wait until next year. Lots of empty lots, rain left a nice crust should be ok if not driven on. Will allow weeds to grow on empty lots.
General Inspection3/5/20203/9/20203/10/2020PPASS
DetailsAndy J. Long
check for water truck/dust controls.

Water truck now staged on site as requested.

No significant trackout. No windblown dust observed. Approved.
General Inspection3/5/20203/5/20203/5/2020PFAIL
DetailsAndy J. Long
No trackout but significant amount of dust due to wind and equipment activity and no water truck or other dust controls at site.

Verbal request to RP Scott to get water truck onsite. He said he has ordered one from Lurre and should be onsite tomorrow.
Tracking Control2/28/20202/28/20202/28/2020PFAIL
DetailsAndy J. Long
Need to sweep gutter and sidewalk on Cole going southbound.

Request sent to RP.
Tracking Control2/10/20202/12/20202/12/2020APASS
DetailsAndy J. Long
Cole apron and gutter, and sidewalks have been thoroughly swept as requested. RP placed barricade to prevent employees driving over sidewalk and causing track out.

Will continue to work on providing more employee parking in a stabilized area. Parking lot for Primary Health should also be installed by March or April.

Approved.
Tracking Control2/10/20202/10/20202/10/2020PFAIL
DetailsAndy J. Long
Workers parking in mud, some driving through mud and over curb instead of using construction entrance.

Correction request to sweep Cole southbound and to thoroughly sweep the gutter. Storm drain on Cole has grate that is asphalt into place so no sediement bag can be installed.

RP said he will work on getting more stabilized parking and have sweeeper come tonight or Tuesday. Follow up inspeciton Wednesday
Tracking Control1/23/20201/28/20201/28/2020APASS
DetailsMichael Zawacki
Street has been swept, entrance improved.
Tracking Control1/23/20201/23/20201/23/2020PCANC
DetailsMichael Zawacki
General Inspection1/23/20201/23/20201/23/2020PFAIL
DetailsMichael Zawacki
Trackout.
Talked to PM, is having PSI come do sweeping, hasn't been happy with CCS, will make sure they get gutters.
Follow up scheduled
Tracking Control12/17/201912/17/201912/18/2019PFAIL
DetailsMichael Zawacki
Both entrances compacted and frozen. Worker parking is on frozen ground. Message sent to RP.
General Inspection12/4/201912/5/201912/5/2019ADONE
DetailsAndy J. Long
correct the area of disturbance

Project listed 1 acre of disturbance on application; 2.05 on ESC plan narrative, and appears to be over 3 acres of disturbance.

Fees have been adjusted accordingly.
Tracking Control12/4/201912/4/201912/4/2019PFAIL
DetailsAndy J. Long
Trackout visibile on Cole Road. Wrong type of rock was used at first and employees parking in muddy areas. Angular rock has now been spread over old rock..

Notified RP that if trackout is a repeated problem we will assess fines and parcel hold as needed.
Requested that they designate a stabilized parking area.

Site work has begun for othe section of parcel. Application only listed 1 acre of disturbance, it looks to be more that that - investigation pending.
General Inspection11/13/201911/14/201911/14/2019APART
DetailsMichael Zawacki
No one on site, message sent to RP with corrections.
No crushed rock ever brought in for entrance, also should be widened at Cole.
Low washout for pumptrucks is full.
Site Preparation10/29/201910/29/201910/29/2019PPASS
DetailsMichael Zawacki
Work begun without calling in siteprep.
Permit displayed on job trailer on southwest of project. Concrete washouts on site. Rock for entrance was delivered while at site, will get load of crushed to put on top of 2".
Inlet protection on Cole. May also use entrance on Cole to access lot.
All utilities for future developments will be done while Primary Health being built. Future plans are also a Maverick and bluebird carwash on corner.