Permit Information
Permit NumberFIR04-00167
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 190 E BANNOCK ST
Project NameSPR ST LUKES ETA SURGERY
Customer Number 
ePlanReview 
Description
(ST LUKES-EAST TOWER-1ST/GROUND/SB FLRS)(ETA SURGERY SUITE)(PHASE 1 & 2) To install automatic fire sprinklers involving the relocation and addition for the build out and occupation of approximately 26,900-ft/2 of area on the ground floor, to be used for surgery suite and support areas. This work will involve some possible selective demolition for the temporarily relocation of certain essential hospital services, which will remain in operation/service. Fire sprinkler work is mainly associated with the construction of new interior non-bearing, fire-resistive walls to create groups of suites for operating rooms and support facilities, non-sleeping hospital suites throughout the ground floor. This project will involve Phases 1 & 2 as indicated on Architectural plan sheet G0.1 (not included), with six future phases requiring separate submittals and permits. Other related work is the fire protection (pits) for two supply service elevator lifts & equipment rooms from the sub-basement to the ground floor. The fire sprinkler system work shall comply with IFC 2000, comment and conditions list, as regulated by the Fire Chief. Comments notes, permit and fire "Inspection Card" are required to be on site as a condition of this work, to provide witness of compliance verification of minimum code. This permit is attached to building permit: BLD03-002465.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection10/14/200410/14/200410/14/2004PPASS
DetailsRick Jackson
INSP-Sprinkler Rough-in/Hydro10/1/200410/1/200410/1/2004PPART
DetailsRick Jackson
doug; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Hydro on sub-basement okay 10/1/2004 3:36:40 PM
INSP-Sprinkler Rough-in/Hydro9/30/20049/30/20049/30/2004PFAIL
DetailsRick Jackson
john; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Sub-basment failed hydro; ground hydro okay 9/30/2004 3:42:27 PM
INSP-Sprinkler Rough-in/Hydro9/27/20049/28/20049/28/2004APART
DetailsRick Jackson
Scheduled by a contractor via Hello! on 9/27/2004 at 12:43:52 PM. Contact: ###-####. Many changes made for this permit due to lights/walls/ducts - will require as-builts at end of project; sub-basement area okay as spacing maintained 9/28/2004 10:39:04 AM
INSP-Sprinkler Rough-in/Hydro9/16/20049/17/20049/17/2004APART
DetailsRick Jackson
Ground floor complete with minor changes due to lights and wall changes 9/17/2004 8:42:41 AM
INSP-Sprinkler Rough-in/Hydro9/16/20049/16/20049/16/2004PCANC
DetailsRick Jackson
Scheduled by a contractor via Hello! on 9/16/2004 at 10:12:25 AM. Contact: ###-####.
INSP-Sprinkler Rough-in/Hydro7/21/20047/22/20047/22/2004PPART
DetailsRick Jackson
Scheduled by a contractor via Hello! on 7/21/2004 at 2:09:23 PM. Contact: ###-####. NW operating room okay to cover 7/22/2004 4:39:07 PM
INSP-Sprinkler Rough-in/Hydro7/21/20047/21/20047/21/2004PNR
DetailsRick Jackson
Scheduled by a contractor via Hello! on 7/21/2004 at 8:02:13 AM. Contact: ###-####. Rescheduled for per Doug 7/21/2004 3:48:30 PM
INSP-Sprinkler Rough-in/Hydro7/8/20047/9/20047/9/2004APART
DetailsRick Jackson
See approved plans for areas okay to cover 7/9/2004 4:14:27 PM
INSP-Sprinkler Rough-in/Hydro7/8/20047/8/20047/8/2004PCANC
DetailsRick Jackson
Scheduled by a contractor via Hello! on 7/8/2004 at 10:37:40 AM. Contact: ###-####. Rescheduled for 7/9 7/8/2004 12:47:35 PM
INSP-Sprinkler Rough-in/Hydro6/21/20046/22/20046/22/2004APART
DetailsRick Jackson
Scheduled by a contractor via Hello! on 6/21/2004 at 2:58:35 PM. Contact: ###-####. Okay to cover hard lid areas as marked on plans; there have been minor changes to head layout but spacing has been maintained; one branch line was moved to the south along the wall to make room for ducts, etc. 6/22/2004 10:43:20 AM
INSP-Sprinkler Rough-in3/31/20043/31/20043/31/2004APART
DetailsRick Jackson
okay for waiting room only; see plans for waiting room detail 3/31/2004 12:30:26 PM