Information based on query as of Friday, August 16, 2024.
Permit Information
Permit NumberFIR05-00156
StatusFinaled
Name AUDIO ELECTRONICS INC
Site Address 9465 W EMERALD
Project NameVIDEO EYE
Customer Number 
ePlanReview 
Description
To provide a required fire sprinkler monitoring fire alarm system that includes HVAC shutdown and elevator recall/shutdown.

3/23/2005 - Additional information regarding the scope of work includes the elevator machinery will be mounted in the pit of the hoistway. Recall shall be dependant upon a smoke detector located in the pit and a smoke detector installed in the top of the hoistway. (apparently requested by the state elevator inspector).

The associated building permit (BLD 04-00300) is to construct a new 37,750 square foot, two story, concrete tilt-up office/warehouse shell and core building and related site improvements. All construction per the approved plans and attached comment list. The core work includes the stairways, elevator and second floor restrooms and corridor. This building will be fully fire sprinklered. This is a shell and core permit only. No occupancy is allowed under this permit. Separate tenant improvement permits will be required to finish this building for occupancy. PC#094-04/DRH03-00167 Mod. #1/JCM Video Eye Corporation (Shell & Core) -

3/23/2005 - The associated building permit (BLD 04-01513) is to construct a tenant space occupying spaces on the first and second floors consisting of 11,249 sq.ft. of warehouse & production area on the 1st floor, and 7,513 sq.ft. of office on the 2nd floor per approved plans. Work to include, construction of accessible restroom on the first floor, construction of interior partitions, installation of suspended ceiling system and lighting, connecting new duct work to existing Hvac system, related interior finishes, this building is fully fire sprinklered any alterations or modifications to the sprinkler system shall be per NFPA #13 as regulated by the fire department. (pc#427-04) rmh (VIDEO EYE)(SUITES 100 & 200)
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection7/19/20057/19/20057/19/2005PPASS
DetailsTroy Cobbley
Fire alarm finaled
INSP-Final Inspection7/15/20057/15/20057/15/2005PCANC
DetailsTroy Cobbley
Request for temp
INSP-Final Inspection7/14/20057/15/20057/15/2005PCANC
DetailsTroy Cobbley
Troy, Here we go again. Please let us know what time will work for you tomorrow. Thanks. Jason (###-####); Phone #: ###-#### Internet Inspection Request from: Jason Minnick Inspection cancelled from web by: Jason Minnick
INSP-Final Inspection7/14/20057/14/20057/14/2005PCANC
DetailsTroy Cobbley
Troy, We would like to schedule an inspection for late this afternoon if at all possible. Around 3:00 would work the best for us, but whatever you could work in would be acceptable. Please call me at ###-####, so that I can have everyone onsite as needed. Thankd Troy. Jason; Phone #: ###-#### Internet Inspection Request from: Jason Minnick Inspection cancelled from web by: Jason Minnick
INSP-Final Inspection7/11/20057/11/20057/12/2005PFAIL
DetailsTroy Cobbley
Provide filter in the duct detector located at hvac unit #34, provide signage on riser room door, provide knox key box, test elevator recall, provide delay for shunt trip, resubmit plans showing the new devices, provide print out of alarm signals, the alarm bell turns on and off when water is flowing, provide map at facp, monitoring company has wrong site address.
FIR-Aging Inspection6/28/20056/28/20056/28/2005 NR
DetailsTroy Cobbley
work is in progress