Permit Information
Permit NumberFIR05-00516
StatusFinaled
Name NORTHWEST SALES COMPANY
Site Address 101 S CAPITOL BLVD Unit: 601
Project Namealm - US BANK-6TH FLR
Customer Number 
ePlanReview 
Description
To provide a new NAC panel on the 6th floor to accommodate total area notification coverage in the remodeled areas per the building permit scope as indicated below. The existing required manual fire alarm system includes sprinkler monitoring, HVAC shutdown, elevator recall/shutdown, fire/smoke damper control, door release and notification throughout (for high rise). The battery, voltage drop and speaker calculations appear to have sufficient capacity. No written comments, PDS Fire Inspector to field verify proper visual spacing and appropriate dB levels. An updated building map shall be provided at time of inspection.

There associated building permit BLD05-01821 is to remodel an existing 2,679 square foot tenant space for a day spa. This space is located on the 6th story of a 19 story building. The floor area of the entire 6th story is about 14,600 square feet. The "core" has a floor area of about 2,670 square feet. The two "core" restrooms were upgraded to be accessible to the disabled under permit BLD03-00539. Work is to include interior nonbearing walls, suspended ceilings, a restroom accessible to the disabled, interior doors, interior windows, millwork, and finishes. The fire sprinkler system, fire alarm system, and high-rise life safety systems (and the infrastructure supporting these systems) for the 6th story are regulated under the provisions of the 2000 IBC. If not already existing, fire-safing shall be installed at the perimeter of the 6th story between the floor and the spandrel glass. The work shall comply with the approved drawings, the plan review report, and all applicable codes. The fire sprinkler system shall comply with NFPA 13 as regulated by the Fire Department. **CJW** (LAUREN MEDISPA - US BANK - STE 601) This building is fire sprinklered because it is a high-rise.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection5/23/20065/23/20065/23/2006PPASS
DetailsForrest France
Fire alarm passed inspection, permit not "doc" finaled as previous inspection request was for alarm testing not final inspection.
INSP-Alarm Testing9/8/20059/9/20059/9/2005APASS
DetailsForrest France
Fire alarm is satisfactory.