Permit Information
Permit NumberFIR06-00440
StatusFinaled
Name IDAHO INTERIOR SPRINKLERS
Site Address 2792 E HARD ROCK DR
Project NameSPR SCOTTSDALE HOMES
Customer Number 
ePlanReview 
Description
To install a (modified) life safety NFPA 13D system in a new four bedroom, two and three quarter bathroom, 3749-ft/2 single story single family dwelling with a 2359-ft/2 main floor and a 1390-ft/2, FINISHED basement and an attached 912-ft/2 three car garage. System shall be equipped with an alarm initiating device and an outside alarm. All fire sprinkler work and related, which includes dual service, single line water supply, the system backflow prevention device (to be installed by others), shall be per NFPA 13D, approved plans, engineering/red-lining and attached review comments, under direction of the Fire Chief. This permit is attached to: BLD05-02593.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection1/12/20071/12/20071/12/2007PPASS
DetailsForrest France
Fire sprinkler permit finaled.
INSP-Final Inspection1/9/20071/11/20071/12/2007AFAIL
DetailsForrest France
Final pending correct wiring for power supply at the flow switch.
INSP-Supply line flush1/9/20071/10/20071/10/2007PFAIL
DetailsTroy Cobbley
kurt; Phone #: ###-#### I called 30 minutes before inspection and got no answer. Nobody at job site knew of kurt. Riser was not set up for flush either. Will need to be rescheduled.
INSP-Sprinkler Rough-in7/25/20067/26/20067/26/2006APART
DetailsForrest France
OH rough-in is acceptable for cover, noted items on previous c/n have been completed, noted possible light fixture obstructions at 1st floor bedroom and one hall due to close proximity to electrical junction boxes, missing drop at one location.
INSP-Final Inspection7/24/20067/24/20067/24/2006PFAIL
DetailsTroy Cobbley
Provide approval notes that accompany the approved plans, tenting is inadequate and needs modified in several locations, provide additional hangers on the 1 1/2" main in the west end of the basement, sidewall heads in the garage appear to be overspaced and provide as-built drawings and hydraulic calculations that include all of the piping changes and hydraulic calculation changes including the slope from the street to the riser