Description |
This fire alarm permit is to add notification in the north bathroom and center storage area, move single station smoke detectors in north office area, add smoke beam detector in core area due to a fireplace installment, and to add smoke detection and notification in expanded dining area. All to be connected to the existing fire alarm system.
Associated building permit: BLD07-01834 (VALLEY VIEW INDEPENDENT LIVING) 6/1/09 - PLAN MODIFICATION #3 TO MODIFY THE MAIN OFFICE/RECEPTION AREA, ADD MECHANICAL ROOMS, DELETE A RESTROOM AND RELOCATE ANOTHER, ADD A SINK TO THE KITCHEN, RELOCATE ICE CREAM EQUIP, SCOPE OF DEMOLITION REDUCED, REVISED EXIT SIGNAGE LOCATION NEARER TO EXITS, CHANGED LIGHT FIXTURES IN CORRIDORS, MODIFY OR RELOCATE CABINETRY, ESTABLISHED OCCUPANT LOAD FOR CONF./MULTI PURPOSE ROOM #3 BY TWO DETAILED SEATING LAYOUTS (TO BE POSTED IN ROOM), NEW MAIL ROOM, INTERIOR FINISH CHANGES, ROOM USE CHANGES, ETC. ALL PER REVIEWED SUBMITTAL PLAN MOD 3 (LIST ATTACHED TO PLANS) drs 5/14/08 PLAN MODIFICATION 2 - MODIFY CENTRAL COMMON CORE, KITCHEN, DINING & SUPPORT AREA; NUMBER OF DOORS, TYPE AND WIDTHS & HARDWARE PER DOOR SCHEDULE; WIDOW CHANGES PER WINDOW SCHEDULE; ELECTRICAL, PLUMBING, MECHANICAL, FIRE SPRINKLER AND ALARM MODIFICATIONS AS PER RESUBMITTED PLAN MODIFICATIONS; CDH & PW REVIEW AND APPROVAL OF NEW SALAD BAR & ICE CREAM AREAS & ASSOCIATED PLUMBING / FIXTURE ADDITIONS; ROOM USE & LAYOUT MODIFIED AND MISCELLANIOUS ITEMS. ALL MODIFICATIONS AND ADDITIONS SHALL COMPLY WITH CURRENT ADOPTED CODES AND ORDINANCES OF BOISE CITY & STATE OF IDAHO REGULATING RESIDENTAIL DWELLING UNITS & COMMON SUPPORT AREAS. drs PLAN MODIFICATION, 3/10/08 - TO MODIFY THE EXTERIOR FINISHES AND APPEARANCE; CHANGE SELECT ROOM USES, EXPAND SELECTED ROOMS; MODIFY ELECTRICAL, MECHANICAL AND PLUMBING PER SUBMITTED PLAN MODIFICATIONS. ALL ORIGINAL PLAN REVIEW CONDITIONS OF ALL REVIEWING AGENCIES AND NOTES PLACED ON PLANS BY SAID AGENCIES SHALL CONTINUE TO APPLY TO THIS PROJECT UNLESS SPECIFICALLY MODIFIED DURING THIS REVIEW PROCESS. drs To remodel the existing independent living facility, to add 1,440 square feet of new floor area to the existing dining room and add a 260 square feet covered entry canopy to the south end of the dining room. Additional work included in this permit is for selective interior remodel, the construction of a new 1690 square feet multi-purpose room, new restrooms on the first floor. There are two existing two-hour area separation walls which must be maintained and there are two existing area separation walls to separate this building from the ALF and the SNF east and west. NOTE: This building is fully fire sprinklered for area increase. All construction shall be per the approved plans and attached comment list. Refer to BLD 07-02235 for the grading and drainage permit. MJP DRH07-00197
|