Permit Number | FIR09-00658 |
Status | Finaled |
Name |
AMERICAN FIRE PROTECTION LLC
|
Site Address |
598 W MAIN ST
|
Project Name | Jimmy Johns TI |
Customer Number | |
ePlanReview | |
Description |
The Fire Sprinkler Scope of work consists of adding sprinklers to a new TI. The existing building is partially sprinkler. The new space is to be entirely sprinklered. The new area has been designed for Ordinary Hazard Group I. The existing riser is 4" and includes a check valve, FDC, and gauges. The new area is connecting at two locations to an existing 4" main apparently in the basement. The new system has a 3" loop and a 3" side feed layout. Hydraulic calculations have been provided for both layouts.
(JIMMY JOHNS - FIRST STORY - SOUTHWEST CORNER) This building is partially fire sprinklered. To convert an existing retail sales tenant space to a restaurant. A small grease trap will be provided but no grease hood. Cooking operations that produce grease laden vapors are NOT allowed. This tenant space will be reduced from 2,765 square feet to 2,150 square feet. Work is to include interior nonbearing walls, 2 restrooms accessible to the disabled, millwork, and finishes. The building fire sprinkler system is required to be extended into this tenant space. Fire sprinkler work is required to comply with NFPA 13 as regulated by the Fire Department. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. **CJW**
|