Permit Number | FIR11-00402 |
Status | Finaled |
Name |
SIMPLEX GRINNELL
|
Site Address |
7009 W FRANKLIN RD
|
Project Name | BISHOP KELLY - SPRINKLER MONIT |
Customer Number | |
ePlanReview | No |
Description |
This quick permit is to provide monitor modules for the newly relocated sprinkler system riser valves. In addition, transient cubes are being provided due to interbuilding circuiting. Inspector to field verify that each interbuilding circuit on is protected by a listed primary protector at each end of the interbuilding circuit. The plans only show the transient cube protection as the circuiting is leaving the building, however they must also be installed when the circuiting enters the riser room per NEC (see redlined plans). There are no written review comments. Assocated building permit: BLD11-00836 Bishop Kelly High School - Administration and Main Entry Remodel and Addition - To demolish and remove approximately 7,100 square feet of existing building that contains administrative offices and a storage garage area. To reconstructed that portion of the building to contain reconfigured administrative offices and accessible restrooms and to constructed a 5,375 square foot addition that will contain a new main entry, lobby/study area, waiting area, new student commons and new mens and womens accessible restrooms. This permit also includes the construction of a new exterior entry plaza and other associate site improvements. This addition and remodel is being done on the northwest side of the high school. All construction per the approved plans and attached comment list. JCM
|