Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberFIR15-00749
StatusFinaled
Name SHILO AUTOMATIC SPRINKLER CO
Site Address 533 E PARKCENTER BLVD
Project NameDistrict@Parkcenter InTown B-1
Customer Number 
ePlanReviewYes
Description
[The District at Park Center - Intown Building B - #1]
The fire sprinkler scope of work consists of protecting a three level apartment building per NFPA 13R. Extended coverage residential sprinklers and CPVC piping are being utilized.
The underground piping is under permit FIR15-00397
(THE DISTRICT AT PARKCENTER - INTOWN BUILDING B - #1) (The drawings are filed under permit BLD14-01818 in ePlanReview) (10-2-15 PLAN MODIFICATION TO CONVERT A STORAGE ROOM LOCATED ON THE 1ST STORY TO A DOGWASH. WORK IS TO INCLUDE A FLOOR SINK, A FLOOR DRAIN, A SMALL WATER HEATER, ELECTRICAL SUPPLY, ELECTRICAL LIGHTING, EXHAUST FAN, AND A TRANSFER GRILL.) (8-25-15 PLAN MODIFICATION TO PROVIDE EXTERIOR EXPANDED POLYSTYRENE FOUNDATION INSULATION IN COMPLIANCE WITH SHALLOW FOUNDATION STANDARDS AT LOCATIONS WHERE THE BOTTOM OF THE FOOTINGS WILL BE LESS THAN 24 INCHES BELOW FINISHED GRADE. THE INTENT IS TO PREVENT FROST HEAVE.) To construct a three story apartment building having a total of 76 dwelling units (24 units 1st story, 26 units 2nd story, and 26 units 3rd story). The 1st story will have a 1,630 square foot storage area with 21 storage units. The interior court on the 1st story will be used for assembly purposes with the egress system passing through the building and sharing the egress system that serves the 1st story apartments. The 1-hr corridors will be enclosed and conditioned and the 1-hr exterior stairways on all stories will be open to the outside. The total floor area of this building is about 81,567 square feet (about 27,189 square feet each story). For building area reasons, this building is divided by a 2-hr fire wall, each side having about 13,550 square feet per story. All ground floor units are required to comply as Type B dwelling units. Because this building does not have an elevator, none of the units located on the 2nd and 3rd stories are regulated for accessibility to the disabled. Work is to include 2-hr fire walls, interior nonbearing walls, 1-hr bearing walls, 1-hr roof-ceiling assemblies, 1-hr floor-ceiling assemblies, 1-hr dwelling unit separations (fire partitions and horizontal assemblies), attic insulation, interior doors, exterior windows and doors, insulated exterior walls, “Hardi-board” exterior siding, exterior manufactured stone wainscot, composition roof shingles, membrane roof coverings for flat roofs, 1-hr common corridors, 1-hr common exterior stairways, draftstops in floors and attics, millwork, and finishes. Structural work includes concrete footings, concrete stem walls, concrete floor slabs on grade with thickened footings at interior bearing walls, wood floor trusses, wood roof trusses, wood columns, wood beams, and shear walls. Special inspection is required for soils, concrete, and wood. The designs for the roof trusses and floor trusses are deferred submittal items. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13R and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection10/25/201610/26/201610/26/2016APASS
DetailsJim Page
Final fire sprinkler inspection passed/complete.