Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberFIR18-00864
StatusFinaled
Name TREASURE VALLEY FIRE PROTECTION
Site Address 350 N MILWAUKEE ST Unit: 1147
Project NameWETZEL'S PRETZELS TI
Customer Number 
ePlanReviewYes
Description
[Wetzel's Pretzels TI] - Quick Permit
INSTALL 12 NEW PENDENT HEADS TO THE NEW WALL AND CEILING LAYOUT.

[BLD18-02873]
Permit is to remodel an existing 940 sq. ft. tenant space for food business use. Approval is contingent upon adhering to the approved plans on file. Work to include: removal of select interior nonbearing walls, removal of select door/door frames, removal of storefront gazing and roll-up gate, removal of select suspended acoustic ceiling, removal od=f select light fixtures, construction of interior non-bearing walls to create a food storage and kitchen area, new kitchen equipment, counters, a new 2’ x 2’ concrete pad, select new suspended acoustic and gypsum ceiling, select new light fixtures, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. Note: This facility includes an engineered smoke control system throughout the mall, any modifications to smoke and/or fire dampers shall be reviewed and approved by the mall engineer, the smoke evacuation system shall remain operational as originally installed under the 1985 UBC. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP-Final Inspection12/13/201812/14/201812/14/2018APASS
DetailsTroy Cobbley
permit finaled

Mike Phone #: 208###-####
INSP-Sprinkler Rough-in12/13/201812/13/201812/13/2018PPASS
DetailsTroy Cobbley
Rough-in passed. All piping can be covered.

Mike Phone #: ###-####
INSP-Sprinkler Rough-in11/26/201811/27/201811/27/2018APASS
DetailsTroy Cobbley
Piping above hardlids is ok for cover.

Mike Phone #: ###-####