Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberGCB13-00023
StatusFinaled
Name Roth Homes
Site Address 10171 W CARLTON BAY
Project NameBLD2013-00023
Customer Number 
ePlanReviewNo
Description
Lot 20 Townhome - **6/24/13 PLAN MODIFICATIONS APPROVED PER PLANS RECIEVED ON 6/19/2013. SRZ** To construct a new 1,844 square foot (902 square foot 1st story / 942 square foot 2nd story), two story, three bedroom, two and a half bathroom, single family dwelling townhouse with a 480 square foot dettached two car garage, and a 33 square foot covered front stoop. All work per the approved plans, attached plan review report, and all other reviewing agencies approvals. 1-hour fire-resistance construction is required on all projections closer than 3 feet to the property line. Distance to property line for fire rated construction is measured from the finished exterior of the exterior wall. Any walls less than 3' from the property line are required to have 1-hour fire-resistance construction. This lot is located within a Floodplain area. **SRZ**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
GCB-Final11/18/201311/19/201311/19/2013PPASS
DetailsJim Sly
Josh ###-#### Call first
Structural final only....OK.
GCB-Energy8/5/20138/5/20138/5/2013PPASS
DetailsJim Sly
Josh ###-####
GCB-Framing8/2/20138/2/20138/2/2013PPART
DetailsMike Jordan
Josh ###-####. ok to insulate.
GCB-Framing7/31/20138/1/20138/1/2013AFAIL
DetailsMike Jordan
Josh ###-####. Complete lateral bracing on C1 and C2P trusses, remove all nonrated boxes from 1 and 2hr walls. Neeeds mech ri inspections.
GCB-Courtesy7/24/20137/24/20137/24/2013PPASS
DetailsTom Arcoraci
Please call first Phone #: ###-####
GCB-Shearwall7/19/20137/19/20137/19/2013PPASS
DetailsTom Arcoraci
Josh ###-#### call first
GCB-Framing6/27/20136/28/20136/28/2013APART
DetailsJim Sly
Josh ###-####
All Nailing for shear and 2hr wall OK at all concealed spaces at all boxed pop outs....Rear and gar. fronts. Note: Need retro fit HD's @ Gar. front portal.
GCB-Fndatn/slab ins/fld vent5/6/20135/6/20135/7/2013PPASS
DetailsJim Sly
Mana ###-####
GCB-Fndatn/slab ins/fld vent5/3/20135/3/20135/3/2013PNR
DetailsJim Sly
Mana ###-####
GCB-Footing4/30/20135/1/20135/1/2013APART
DetailsMike Jordan
MANA ###-####
Between 9-10. Needs to replace some form boards to meet min. footing depths.
GCB-Footing4/29/20134/29/20134/29/2013PCANC
DetailsTony Young
MANA ###-####