Permit Information
Permit NumberGCB15-00034
StatusFinaled
Name ASIN GENERAL CONTRACTORS
Site Address 3590 N PROSPECT
Project NameBLD2015-00034
Customer Number 
ePlanReviewNo
Description
Lot 5 Townhouse - To construct a new 2,118 square foot, Three story (456 square foot 1st story / 822 square foot 2nd story / 840 square foot 3rd story), two bedroom, three and one half full bathroom, single family dwelling townhouse with a 445 square foot attached garage, a 96 square foot covered rear 2nd story balcony, a 96 square foot covered rear 3rd floor balcony, and a 12 square foot covered stoop. All work per the approved plans, attached plan review report, engineering, and all other reviewing agencies approvals. 1-hour fire-resistance construction is required on all projections closer than 3 feet to the property line. Distance to property line for fire rated construction is measured from the finished exterior of the exterior wall. Any walls less than 3' from the property line are required to have 1-hour fire-resistance construction. FEMA (LOMR-F) determination letter attached to plans removing this property from the floodplain. ENGINEERED DESIGN FOR SHEAR WALLS PER DESIGN PROFESSIONAL. NOTE: This house shall be fitted with a sprinkler system and WILL REQUIRE A SEPARATE PERMIT, and shall be installed per NFPA #13D as regulated by N.A.C.F.R. rules.**SRZ**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
GCB-Final3/29/20163/30/20163/30/2016APASS
DetailsJim Sly
Scott ###-#### - code: 2746
GCB-Final3/28/20163/29/20163/29/2016ANR
DetailsJim Sly
Scott ###-#### - code: 2746
Contractor office# ###-####
Walk thru......Not ready. Need Plumb final, Fire Final? Guards on Stairway and decks. Landings at doorways. Bottom riser at stairway to 2nd floor over 7 3/4 " Doing final coat on stucco now.
GCB-Energy1/20/20161/21/20161/21/2016APASS
DetailsMike Jordan
Todd ###-#### - exterior insulation and sheetrock
GCB-Energy1/19/20161/20/20161/20/2016APASS
DetailsMike Jordan
Todd ###-####. Al framing issues were resolved. Plumbing rough in inspection done. Energy code ok.
GCB-Framing1/6/20161/6/20161/6/2016PPART
DetailsJim Sly
Todd ###-####
C/N issued .....Stair issues, hold downs, bored parralam in garage.
GCB-Framing12/14/201512/14/201512/14/2015PDONE
DetailsDave Hannah
Todd ###-#### - FRAMING CONSULTATION ONLY needs engineering to drill beams
GCB-Fndatn/slab ins/fld vent9/17/20159/18/20159/18/2015APASS
DetailsPhil Shearer
Manuel ###-####
GCB-Footing9/14/20159/15/20159/15/2015PPASS
DetailsJim Sly
Ryan ###-####
GCB-Footing9/11/20159/14/20159/14/2015AFAIL
DetailsMike Jordan
Ryan ###-####. F8 column pad footing missing rebar, Center footings needs #4 verts at 32" o.c. Correction notice posted.
GCB-Footing9/10/20159/11/20159/11/2015PNR
DetailsMike Jordan
Ryan ###-####. No approved plans or engineering on site. No concrete allowed at this time. Will need to reschedule.
GCB-Footing8/14/20158/17/20158/17/2015PCANC
DetailsDave Hannah
Ryan ###-####