GCE-Final | 3/9/2016 | 3/9/2016 | 3/9/2016 | P | PASS |
Eric Story
|
|
|
###-#### - code: 2727 corrections fixed final ok
|
GCE-Final | 3/1/2016 | 3/1/2016 | 3/1/2016 | P | FAIL |
Rock A. Hudson
|
|
|
###-#### - code: 2727 210.12- All 15 or 20 amp 120 volt outlets located in a bedroom shall have AFCI protection. 210.52(3)- Receptacles required be 210.52 shall be in addition to those located in cabinets. Master bed receptacle with 6' of door south wall. 210.70(A)(1)- At least 1 outlet controlled by wall switch shall be located in habitable rooms. Family room. 422.31(B)- Microwave shall have an accessible disconnecting means. 110.25- lockout acceptable.
|
GCE-Rough-In Permanent Service | 10/15/2015 | 10/15/2015 | 10/15/2015 | P | PASS |
Rock A. Hudson
|
|
|
Daniel ###-#### Rough in ok cover p/s u/g n ok
|