Final | 8/2/2017 | 8/2/2017 | 8/2/2017 | P | PASS |
Bill VanDegrift
|
|
|
reinspection on water heaters and furnace installed in 2003, needed stickers for state licensing.
|
Final | 7/27/2017 | 7/27/2017 | 7/27/2017 | P | FAIL |
Bill VanDegrift
|
|
|
Elena-w/h Phone #: ###-####
went by to put final stickers on the furnace and waterheaters but one water heater was in a bedroom that one will need a solid sealed door with all combustion air from the outside and the water heater flex removed from the relief line it also needs 6 inches of clearance at the single wall flue at the shelf above. the water heater in the hallway needs the water heater flex removed from the relief line. the furnace is ok.
|
Pressure Test | 8/6/2003 | 8/7/2003 | 8/7/2003 | A | PASS |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 8/6/2003 at 3:34:55 PM. Contact: ###-####. pressure test only ok 8/7/2003 10:14:09 AM
|
Pressure Test | 8/5/2003 | 8/6/2003 | 8/6/2003 | A | FAIL |
Dave Lightfoot
|
|
|
BILLIE; Phone #: ###-#### Internet Inspection Request from: Darla Downs
|
Rough-in | 8/5/2003 | 8/6/2003 | 8/6/2003 | A | PASS |
Dave Lightfoot
|
|
|
BILLIE R/I FOR FURN ONLY; Phone #: ###-#### Internet Inspection Request from: Darla Downs
|