Final | 6/13/2006 | 6/14/2006 | 6/14/2006 | A | PASS |
Dixie Fellows
|
|
|
dave - kb burritos 9am as per dixie; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
|
Conference | 6/13/2006 | 6/13/2006 | 6/13/2006 | A | PASS |
Dixie Fellows
|
|
|
###-####..went over corrections with journeyman..
|
Final | 6/9/2006 | 6/12/2006 | 6/13/2006 | A | NR |
Dixie Fellows
|
|
|
rod ###-####..this should have been a conference for corrections
|
Final | 6/8/2006 | 6/9/2006 | 6/9/2006 | A | PEND |
Dixie Fellows
|
|
|
Dave Godfrey is your contact ; Phone #: ###-#### Internet Inspection Request from: Samantha Patterson..will review air-balance report..unable to make inspection today..i called scott and let him know i would reschedule this for monday at 8:45...the phone # for my contact on the job was typed in wrong as i called somebody who had no idea what i was talking about..thanks dixie
|
Final | 6/7/2006 | 6/8/2006 | 6/8/2006 | A | NR |
Dixie Fellows
|
|
|
Pat Nichols is your contact ; Phone #: ###-#### Internet Inspection Request from: Samantha Patterson..need air balance on site..rod will reschedule for fri am
|
Conference | 6/5/2006 | 6/6/2006 | 6/6/2006 | A | PEND |
Dixie Fellows
|
|
|
pat called and said that Dixie had the conference on 6/05 //blb pat; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley...need to fire-wrap top of hood due to clearance issues from ceiling..fire-wrap around grease duct above hood not per manufacturer
|
Conference | 6/1/2006 | 6/2/2006 | 6/2/2006 | A | PASS |
Dixie Fellows
|
|
|
Pat Nichols is your contact; Phone #: ###-#### Internet Inspection Request from: Samantha Patterson...welds at duct to hood connection need to be smooth..bolt all equipment on roof..need to protect grease duct on roof..oil pan, ets
|
Rough-in | 4/17/2006 | 4/18/2006 | 4/18/2006 | A | PART |
Dixie Fellows
|
|
|
Pat is contact.; Phone #: ###-#### Internet Inspection Request from: Amanda Turner..wall behind hood ok to re-cover with rock..duct detectors in place..ok to cover lid
|
Rough-in | 4/17/2006 | 4/17/2006 | 4/17/2006 | P | FAIL |
Dixie Fellows
|
|
|
Pat Nichols is contact ; Phone #: ###-#### Internet Inspection Request from: Samantha Patterson...remove pink batting behind sheetrock on wall where type 1 hood will be installed
|
Rough-in | 4/14/2006 | 4/17/2006 | 4/17/2006 | A | PEND |
Dixie Fellows
|
|
|
Jason Heaton is your contact ; Phone #: ###-#### Internet Inspection Request from: Samantha Patterson...rescheduled for pm..inspector meeting
|
Rough-in | 3/28/2006 | 3/29/2006 | 3/29/2006 | A | PART |
Dixie Fellows
|
|
|
Contact Aaron Hodges for 8:45am rough in inspection, Thank you ; Phone #: ###-#### Internet Inspection Request from: steve hasse...ducts all sealed and ok to insulate...grease duct fire wrapped ok and fine to cover with shaft
|
Rough-in | 3/28/2006 | 3/28/2006 | 3/28/2006 | P | NR |
Dixie Fellows
|
|
|
Aaron hodges is your contact ; Phone #: ###-#### Internet Inspection Request from: Samantha Patterson..unable to meet aaron before he had to leave..reschedule for wed am
|
Rough-in | 3/21/2006 | 3/22/2006 | 3/22/2006 | A | PART |
Dixie Fellows
|
|
|
Aaron Hodges ; Phone #: ###-#### Internet Inspection Request from: Samantha Patterson...discussed clearance from bath exhausts to fresh air intakes to equipment.. need to be 10' away or 3' above fresh air
|
Rough-in | 3/20/2006 | 3/20/2006 | 3/20/2006 | P | PART |
Dixie Fellows
|
|
|
jason ###-####..inside welds ok
|
Conference | 3/17/2006 | 3/20/2006 | 3/20/2006 | A | PASS |
Dixie Fellows
|
|
|
Aaron Hodges is your contact.; Phone #: ###-#### Internet Inspection Request from: Samantha Patterson...talked with jason about inside welds on grease duct
|
Rough-in | 3/15/2006 | 3/15/2006 | 3/15/2006 | P | PART |
Dixie Fellows
|
|
|
Jason Heaton is your contact. This is for the grease duct.; Phone #: ###-#### Internet Inspection Request from: Samantha Patterson..HAD JASON COVER END OF HORIZONTAL GREASE DUCT AND I LOOKED FOR PIN HOLES.. I WILL CONTINUE TO CHECK THE REST OF THE DUCT AS THEY GET THE WELDS SMOOTHED OUT ON THE INSIDE OF THE DUCT.
|
Conference | 3/14/2006 | 3/14/2006 | 3/15/2006 | P | PART |
Dixie Fellows
|
|
|
Aaron Hodges is the contact. ; Phone #: ###-#### Internet Inspection Request from: Samantha Patterson..looked at welds in horizonal grease duct as they had alot of slag and pin holes
|
Rough-in | 3/10/2006 | 3/10/2006 | 3/10/2006 | P | FAIL |
Dixie Fellows
|
|
|
This is an inspection for grease duct only. AARON HODGES IS YOUR CONTACT ; Phone #: ###-#### Internet Inspection Request from: Samantha Patterson..grease duct has pin holes...inside welds need to be ground down and smoothed out..i need to be able to inspect the inside of the duct from start to termination
|