Final | 8/9/2007 | 8/9/2007 | 8/9/2007 | P | CANC |
Troy James
|
|
|
Jason Phone #: ###-#### Internet Inspection Request from: Frank Marturello
|
Final | 8/9/2007 | 8/9/2007 | 8/9/2007 | A | PASS |
Troy James
|
|
|
|
Final | 8/8/2007 | 8/8/2007 | 8/8/2007 | P | FAIL |
Troy James
|
|
|
jason ###-#### call after 2:00pm 3" cap at y at flue, gas flex connector cannot be inside furnace
|
Final | 6/8/2006 | 6/9/2006 | 6/9/2006 | A | NR |
Troy James
|
|
|
Dixie: Call Greg to meet.; Phone #: ###-#### Internet Inspection Request from: Frank Marturello
|
Rough-in | 6/9/2006 | 6/9/2006 | 6/9/2006 | A | PASS |
Troy James
|
|
|
Dixie: Call Greg to meet.; Phone #: ###-#### Internet Inspection Request from: Frank Marturello r/i inspection verified by dixie c/n ok to cover
|
Final | 6/2/2006 | 6/5/2006 | 6/5/2006 | A | FAIL |
Troy James
|
|
|
Phone #: ###-#### Internet Inspection Request from: Frank Marturello c/n posted
|
Conference | 5/30/2006 | 5/31/2006 | 5/31/2006 | A | PASS |
Dixie Fellows
|
|
|
Phone #: ###-#### Internet Inspection Request from: Frank Marturello..discussed clearance from cabinets to gas range..need to seal and insulate duct..pan of r/a in chase..move bath exhaust upstairs..1/4" slope on flue upstairs and 1" clearance from shield to b-vent..dryer vent exceeds lenght allowed..some duct work left undone
|
Rough-in | 5/26/2006 | 5/30/2006 | 5/30/2006 | A | NR |
Dixie Fellows
|
|
|
Phone #: ###-#### Internet Inspection Request from: Frank Marturello..reschedule for wed am..have installer meet me there
|