Final | 8/18/2006 | 8/18/2006 | 8/18/2006 | P | PASS |
Troy James
|
|
|
carl- call 1hr prior to meet; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
|
Final | 8/16/2006 | 8/17/2006 | 8/17/2006 | A | NR |
Dixie Fellows
|
|
|
Carl; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt..waiting for other contractors to finish and call for their finals
|
Conference | 8/7/2006 | 8/8/2006 | 8/8/2006 | A | PASS |
Troy James
|
|
|
Carl; Phone #: ###-#### 10:00 mtg. at job site Internet Inspection Request from: Cathy Weisshaupt grease duct ok to wrap and paint
|
Rough-in | 8/4/2006 | 8/7/2006 | 8/7/2006 | A | PEND |
Dixie Fellows
|
|
|
carl - call 1hr prior for access; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley...inspector please reschedule for tues am
|
Rough-in | 8/3/2006 | 8/4/2006 | 8/4/2006 | A | FAIL |
Troy James
|
|
|
carl - call 1hr prior for access; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley called and left message, no response back
|
Rough-in | 8/2/2006 | 8/3/2006 | 8/3/2006 | A | PEND |
Dixie Fellows
|
|
|
Carl, pls call 30 min. prior; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt..rescheduled for fri am
|
Conference | 7/31/2006 | 7/31/2006 | 7/31/2006 | P | PASS |
Dixie Fellows
|
|
|
dixie
|
Rough-in | 7/31/2006 | 7/31/2006 | 7/31/2006 | A | FAIL |
Dixie Fellows
|
|
|
karl ###-####..this was a partial to check welds on grease duct..had contractor cut openings for clean-outs to check inside welds. found some pinholes so lee will re-weld, cut some more openings to check rest of inside duct and call for another inspection..met with insul-co to discuss duct wrap
|
Rough-in | 7/25/2006 | 7/26/2006 | 7/26/2006 | P | NR |
Dixie Fellows
|
|
|
Partial rough in . Please have Dixie meet Karl on site. Call 1/2 hour before arrival.; Phone #: ###-#### Internet Inspection Request from: joe paige..karl and i couldn't meet today..he will reschedule for mon am.
|
Conference | 7/18/2006 | 7/19/2006 | 7/19/2006 | A | PASS |
Dixie Fellows
|
|
|
lee; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley...discussed grease duct
|
Conference | 7/17/2006 | 7/18/2006 | 7/18/2006 | A | FAIL |
Dixie Fellows
|
|
|
meet lee at 9:00 ###-####..other contractor didn't obtain a permit and call for a conference
|
Conference | 7/17/2006 | 7/18/2006 | 7/18/2006 | A | FAIL |
Dixie Fellows
|
|
|
dennis ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie..bsr didn't get a permit and call for a conference. i told the g/c to get all contractors to schedule for a conference at one time
|
Conference | 7/14/2006 | 7/17/2006 | 7/17/2006 | A | NR |
Dixie Fellows
|
|
|
lee; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley..trying to schedule everybody for tues am at 9:00
|