DOC - Permit Expired | | | 7/9/2008 | | DONE |
Tisha Gallop
|
|
|
no activity on this project over expiration date, building permit has been expired 7/9/08 LEG
|
MEC-Aging Inspection | 6/11/2008 | 6/11/2008 | 6/11/2008 | | PASS |
Dixie Fellows
|
|
|
wip
|
Final | 4/4/2008 | 4/7/2008 | 4/7/2008 | A | NR |
Dixie Fellows
|
|
|
final - travis Phone #: ###-#### Internet Inspection Request from: Brandon Sorensen...callled in wrong permit so i called travis
|
MEC-Aging Inspection | 1/11/2008 | 1/11/2008 | 1/11/2008 | | PASS |
Bill VanDegrift
|
|
|
|
MEC-Aging Inspection | 10/25/2007 | 10/25/2007 | 10/26/2007 | | CANC |
Troy James
|
|
|
job shut down, wait till dixie gets back
|
Final | 8/17/2007 | 8/20/2007 | 8/20/2007 | A | CANC |
Dixie Fellows
|
|
|
final Phone #: ###-#### Internet Inspection Request from: Brandon Sorensen..unable to do am inspection due to meeting..called luke
|
Final | 7/6/2007 | 7/6/2007 | 7/6/2007 | P | PART |
Dixie Fellows
|
|
|
temp occ ok
|
Rough-in | 7/5/2007 | 7/6/2007 | 7/6/2007 | A | PASS |
Dixie Fellows
|
|
|
re-inspect Phone #: ###-#### Internet Inspection Request from: Brandon Sorensen..will add one more barrier in front of flues
|
Conference | 7/5/2007 | 7/5/2007 | 7/5/2007 | A | PASS |
Dixie Fellows
|
|
|
ok to use concentric vent kit..super will modify protection barrier in back
|
Rough-in | 7/5/2007 | 7/5/2007 | 7/5/2007 | P | NR |
Dixie Fellows
|
|
|
Re-inspect Phone #: ###-#### Internet Inspection Request from: Brandon Sorensen..i scheduled this for a conference
|
Rough-in | 7/5/2007 | 7/6/2007 | 7/5/2007 | A | CANC |
Dixie Fellows
|
|
|
Re-inspect Phone #: ###-#### Internet Inspection Request from: Brandon Sorensen Inspection cancelled from web by: Brandon Sorensen
|
Conference | 7/2/2007 | 7/3/2007 | 7/3/2007 | A | PEND |
Dixie Fellows
|
|
|
meet lee and luke at 9:00..left c/n...horizonal venting on both w/h exceed the allowable length and elbows per manuf
|
Conference | 6/29/2007 | 7/2/2007 | 7/2/2007 | A | PEND |
Dixie Fellows
|
|
|
meet lee to go over venting on w/h...lee unable to make it today due to meetings..i rescheduled for tues am and called luke
|
Rough-in | 6/28/2007 | 6/29/2007 | 6/29/2007 | A | PASS |
Dixie Fellows
|
|
|
rough Phone #: ###-#### Internet Inspection Request from: Brandon Sorensen...ok to cover ceiling
|
Rough-in | 6/27/2007 | 6/28/2007 | 6/28/2007 | A | PEND |
Dixie Fellows
|
|
|
cover inspection Phone #: ###-#### Internet Inspection Request from: Brandon Sorensen/...meeting all a.m...luke will reschedule for fri am
|
Rough-in | 6/22/2007 | 6/25/2007 | 6/25/2007 | A | FAIL |
Dixie Fellows
|
|
|
Cary Reynolds will bring manufactures install book.Please call to schedule time. Phone #: ###-#### Internet Inspection Request from: Dave Tully..due to different opinions from engineering dept of w/h, i have asked for a stamped,signed letter from the engineer addressing the venting length, rise per foot and ability of comb air fan to draw back to w/h from distance
|
Rough-in | 6/21/2007 | 6/22/2007 | 6/22/2007 | A | FAIL |
Dixie Fellows
|
|
|
rough/cover Phone #: ###-#### Internet Inspection Request from: Brandon Sorensen...venting length on 2 w/h exceed the manufacturer allowance..i called sarah in the technical dept and spoke with her
|
Rough-in | 5/24/2007 | 5/25/2007 | 5/25/2007 | A | PASS |
Dixie Fellows
|
|
|
rough Phone #: ###-#### Internet Inspection Request from: Brandon Sorensen
|
Rough-in | 5/1/2007 | 5/2/2007 | 5/2/2007 | A | PART |
Dixie Fellows
|
|
|
rough-in Phone #: ###-#### Internet Inspection Request from: Brandon Sorensen..CHECKED SHAFTS WITH FRESH AIR AND BATH EXHAUSTS FROM 2ND FLOOR THROUGH 3RD FLOOR..ALL DRYER VENTS WERE ENGINEERED BY MUSGROVE AS THEY EXCEED CODE LENGTHS ALLOWED..LACK OF FIRE DAMPERS IN SOME PENETRATIONS PER PLAN WERE PASSED ON TO STRUCTURAL INSPECTOR..
|
Rough-in | 4/26/2007 | 4/27/2007 | 4/27/2007 | A | PART |
Dixie Fellows
|
|
|
Rough - Luke Phone #: ###-#### Internet Inspection Request from: Brandon Sorensen..f/p flues on 3rd floor ok..duct ok to insulate..w/h flues ok in wall
|
Rough-in | 4/16/2007 | 4/17/2007 | 4/17/2007 | A | PASS |
Dixie Fellows
|
|
|
Courtesy inspection Phone #: ###-#### Internet Inspection Request from: Brandon Sorensen...ok to insulate all ductwork on 3rd floor
|
Rough-in | 4/6/2007 | 4/9/2007 | 4/9/2007 | A | PART |
Dixie Fellows
|
|
|
rough Phone #: ###-####..ok to insulate duct on 2nd floor..left c/n for ifgc section 305.5..need 50 cubic feet for every 1,000btu for range and f/p..dixie
|