Final | 9/17/2009 | 9/17/2009 | 9/17/2009 | P | PASS |
Bill VanDegrift
|
|
|
Home owner said they would be home Phone #: ###-#### Internet Inspection Request from: Veronica Shipley
|
Final | 9/14/2009 | 9/16/2009 | 9/16/2009 | P | FAIL |
Bill VanDegrift
|
|
|
Internet Inspection Request from: Veronica Shipley min. 6" clearance from single wall furnace flue to combustables, replace with B-vent. remove water heater flex from t&p line, hardpipe. provide weep hole in low point of t&p line.
|
Final | 9/11/2009 | 9/15/2009 | 9/14/2009 | P | CANC |
Bill VanDegrift
|
|
|
INSTALLER SAM ###-#### Phone #: ###-#### Internet Inspection Request from: Veronica Shipley Inspection cancelled from web by: Veronica Shipley
|