Final | 5/23/2011 | 5/24/2011 | 5/24/2011 | P | PASS |
Bill VanDegrift
|
|
|
Upper level (attic) system is heat only, I am told that is why you can not find a primary or secondary condensate lines. Ductwork in basement is all insulated on the inside. Call with any questions. Thanks! Phone #: ###-#### >> Inspection requested via web by April Sims
|
Final | 5/11/2011 | 5/12/2011 | 5/12/2011 | P | FAIL |
Dixie Fellows
|
|
|
Lockbox 1741 Phone #: ###-#### >> Inspection requested via web by April Sims...location of attic furn primary and secondary condensate lines...complete gas to w/h..extend furn flue out from under eve..insulate all duct in basement (unconditioned).
|
MEC-Aging Inspection | 4/6/2011 | 4/6/2011 | 4/7/2011 | | PASS |
Dixie Fellows
|
|
|
wip
|
MEC-Aging Inspection | 2/4/2011 | 2/4/2011 | 2/11/2011 | | PASS |
Dixie Fellows
|
|
|
wip
|
Rough-in | 11/15/2010 | 11/15/2010 | 11/15/2010 | P | PASS |
Dixie Fellows
|
|
|
Phone #: ###-#### >> Inspection requested via web by April Sims
|
Pressure Test | 11/10/2010 | 11/10/2010 | 11/10/2010 | P | PASS |
Dixie Fellows
|
|
|
Late afternoon. Thanks! Phone #: ###-#### >> Inspection requested via web by April Sims...20LB GAS OK
|
Rough-in | 11/10/2010 | 11/10/2010 | 11/10/2010 | P | FAIL |
Dixie Fellows
|
|
|
Late afternoon. Thanks! Phone #: ###-#### >> Inspection requested via web by April Sims...ELEC WIRES IN R/A
|